Experimental and Theoretical Studies on Hysteretic Behavior of Friction Energy Dissipation Composite Chord under
Qishi Zhou1, Wenwu He1, Zhibin Zhou1
1School of Civil Engineering, Central South University, Changsha 410075, China.
Abstract:
To improve the seismic performance of a staggered truss steel framing system, the basic force unit in the truss system is replaced by a friction energy dissipation truss. The difference between a friction energy dissipation truss and an ordinary truss is that the upper chord is a friction energy dissipation composite chord. In this paper, we investigate the effects of the number of bolts and the friction surface on the energy dissipation capacity of the chord by a quasi-static test on six composite chord specimens at a scale of 1:2. The results show that the hysteresis curves of friction energy dissipation composite chords are ideal rectangles, and the energy dissipation capacity is excellent. The more bolts there are in the specimen, the slower the energy dissipation capacity of the chord decreases. Among the different friction surface specimens, the energy dissipation capacity of the aluminum friction plate specimen decays the fastest, while the energy dissipation capacity of the shot-blasted treated specimen decays substantially after the first cycle. Friction plates can improve the stability of the hysteresis properties. Based on the test results, this paper proposes a calculation method for the ultimate bearing capacity of the composite chord, which provides a basis for the design of a friction energy dissipation truss. In addition, we studied the effects of different bolt clamping forces and slotted bolt hole lengths on the energy dissipation capacity of composite chords by establishing a finite element analysis. It was shown that as the clamping force of the bolt increases, the energy dissipation capacity of the specimen becomes stronger but the stability decreases. The energy dissipation capacity of the chord is close to a linear relationship with the slotted bolt hole lengths; thus, increasing the slotted bolt hole lengths within the allowable range of inter-story drifts can enhance the energy dissipation capacity of the chord. Finally, we propose the design method of the angle steel by analyzing the force of the chord.
Related Concept Videos
Static and Kinetic Frictional Force
However, if two systems are in contact and are stationary relative to one...
Characteristics of Dry Friction
Before the wheelbarrow starts moving, the static frictional force acts tangentially to the contact surface, opposing the force that is about to induce the motion. This frictional force prevents the...
Elastic Strain Energy for Shearing Stresses
Types of Friction Problems
The first type of dry friction problem involves situations where there is no apparent impending motion....
Bending of Members Made of Several Materials
Hooke's Law determines stress in each material, stating that stress is proportional to strain but varies due to each...
Behavior of Concrete Under Compressive Load
As the concrete specimen fractures under...


