Related Experiment Video
Updated: Aug 2, 2025

Electrochemical Preparation of Poly3,4-Ethylenedioxythiophene Layers on Gold Microelectrodes for Uric Acid-Sensing Applications
Published on: July 28, 2021
Voltammetric Detection of Vanillylmandelic Acid and Homovanillic Acid Using Urea-Derivative-Modified Graphite
Tatiana V Shishkanova1, František Králík1, Alla Synytsya1
1Department of Analytical Chemistry, University of Chemistry and Technology, Technická 5, 166 28 Prague, Czech Republic.
Abstract:
Vanillylmandelic acid (VMA) and homovanillic acid (HVA) are diagnostic markers of neuroblastoma. The purpose of this study was to understand the reason for the discrimination of structural analogues (VMA and HVA) onto a graphite electrode coated with an electrochemically oxidized urea derivative. Density functional theory calculations (DFT), FTIR spectroscopic measurements, and electrochemical impedance spectroscopic measurements were used in this work. Density functional theory calculations (DFT) were used to identify the most suitable binding sites of the urea derivative and to describe possible differences in its interaction with the studied analytes. The FTIR measurement indicated the enhancement and disappearance of NH vibrations on graphite and platinum surfaces, respectively, that could be connected to a different orientation and thus provide accessibility of the urea moiety for the discrimination of carboxylates. Additionally, the higher the basicity of the anion, the stronger the hydrogen-bonding interaction with -NH-groups of the urea moiety: VMA (pKb = 10.6, KAds = (5.18 ± 1.95) × 105) and HVA (pKb = 9.6, KAds = (4.78 ± 1.58) × 104). The differential pulse voltammetric method was applied to detect VMA and HVA as individual species and interferents. As individual analytes, both HVA and VMA can be detected at a concentration of 1.99 × 10-5 M (RSD ≤ 0.28, recovery 110-115%).
Related Concept Videos
Voltammetry: Overview
A voltammetric cell uses three electrodes: a working electrode, a reference electrode, and an auxiliary electrode. The redox reactions occur in the working...
Voltammetric Techniques: Linear-Scan (E vs Time)
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
Voltammetric Techniques: Pulse Voltammetry
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Voltammograms: Overview
Shapes of Voltammograms

