Sugammadex is a medication that may have cost considerations with the potential for waste of unused product in pediatric patients due to the vial size and its single-use limitation. Therefore, exploring the potential of vial-splitting for perioperative use may be beneficial.
Methods:
The study was a retrospective, quality improvement study using the electronic medical record to identify every sugammadex administration over the last five years in a tertiary care pediatric institution. We divided patients into groups depending on the dose of sugammadex administered. The cost of sugammadex was calculated under three scenarios: (1) only 200-mg vials available; (2) 100-mg aliquots available; and (3) 50-mg aliquots. We then calculated the total money spent per patient in the 3 scenarios.
Results:
31,063 patients received sugammadex over the study period, of whom 23.6% received 151-200 mg. The greatest percentage of patients received ≤50 mg (32.9%). The average cost per patient was $113.58, $81.61, and $68.83 if 200 mg, 100 mg, and 50 mg doses were available, respectively. Over the last 5 years, $1,390,110.13 could have been saved by having 50 and 100 mg aliquots available.
Conclusions:
Pediatric patients generally receive lower doses of sugammadex due to weight-based dosing, leading to increased waste and cost when using only 200-mg vials. Vial-splitting into smaller aliquots can significantly cut costs for healthcare centers and patients while decreasing waste.