Related Experiment Video
Updated: Aug 2, 2025

Avocado Sample Preparation Using the QuEChERS Method with Ammonium Formate for Pesticide Analysis
Published on: December 8, 2023
Development and validation of gas chromatography with electron capture detection method using QuEChERS for pesticide
Javid A Sofi1, Alamgir A Dar1, Ishrat Jan1
1Research Centre for Residue and Quality Analysis, Faculty of Horticulture, Sher-e-Kashmir University of Agricultural Sciences and Technology (SKUAST-K), Shalimar Campus, Srinagar, India.
Abstract:
A modified quick, easy, cheap, efficient, rugged, and safe (QuEChERS) method coupled to gas chromatography with electron capture detection was developed for the simultaneous determination of selected electronegative pesticides, namely, chlorpyrifos-methyl (1), chlorpyrifos (2), quinolphos (3), profenofos (4), myclobutanil (5), ethion (6), fenpropathrin (7), and cypermethrin (8), in vegetables with high water content. The selected compounds and some of their metabolites have even been found in human body fluids. In addition, some of them are known or suspected carcinogens according to the World Health Organization. Extraction and cleanup parameters were optimized; thus, the original QuEChERS method was modified to minimize solvent usage by making the study eco-friendly. The developed method was validated for selectivity, specificity, linearity, precision, and accuracy using SANTE guidelines. Calibration curves showed good linearity (r > 0.99) within the test range. Precision was evaluated by intra- and inter-day experiments with an acceptable range of less than 20.0% of relative standard deviation. Recovery was evaluated at limit of quantification and was found to be in the range of 70-120%, with relative standard deviations lower than 4.21%. The proposed method is applicable for detection and monitoring of selected pesticides in one run not only in fruits and vegetables with high water content but also in samples containing large quantities of pigments/dyes.
Related Concept Videos
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Types of Detectors-II
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...

