Establishment of a Simple and Effective Rat Model for Intraoperative Parathyroid Gland Imaging
Published on: August 17, 2022
Evaluation of Surgeon-Performed Ultrasonography With or Without Contrast Enhancement vs Scintigraphy in Patients With
Sanne Høxbroe Michaelsen1,2, Mette Bay1, Oke Gerke2,3
1Research Unit for ORL-Head & Neck Surgery and Audiology, Odense University Hospital, Odense, Denmark.
Importance:
Scintigraphy and ultrasonography are common imaging modalities for the preoperative localization of enlarged parathyroid glands in primary hyperparathyroidism. When comparing the 2 modalities, the benefits of ultrasonography in terms of convenience, patient comfort, duration, cost, and lack of radiation should be taken into account.
Objective:
To investigate whether surgeon-performed ultrasonography, with or without contrast-enhanced ultrasonography (CEUS), is noninferior to scintigraphy for localizing pathological parathyroid glands in patients with primary hyperparathyroidism.
Design, Setting, And Participants:
Prospective, paired, noninferiority cohort study performed at a high-volume tertiary referral center for parathyroidectomy with blinded examiners and a 6-month follow-up. Participants were adults (age ≥18 years) referred for parathyroidectomy due to primary hyperparathyroidism. Of 207 eligible patients, 35 were excluded, leaving 172 enrolled in the study. Inclusion lasted from September 2019 until February 2021. Follow-up ended in December 2021.
Exposures:
99mTechnetium-pertechnetate/99mtechnetium-sestamibi subtraction scintigraphy with 99mtechnetium-sestamibi single-photon emission computed tomography/computed tomography, followed by surgeon-performed ultrasonography and CEUS.
Main Outcomes And Measures:
The sensitivity of each imaging modality in localizing pathological parathyroid glands, calculated on a per-quadrant and a per-patient basis, respectively. The a priori noninferiority margin was a lower 95% confidence limit for the difference in sensitivity not falling below -10%.
Results:
Out of 172 participants, 139 (80.8%) were women, the median (range) age was 65 (24-87) years, and the median (IQR) follow-up was 200.5 (181-280.25) days. Quadrant sensitivity (95% CI) was 70.9% (63.2%-78.5%) for ultrasonography, 68.4% (60.4%-76.5%) for ultrasonography plus CEUS, and 67.0% (60.0%-74.0%) for scintigraphy. The sensitivity difference (95% CI) compared with scintigraphy was 3.9% (-4.1% to 11.8%) for ultrasonography and 1.5% (-6.4% to 9.3%) for ultrasonography plus CEUS, establishing noninferiority for both modalities. Per-patient sensitivity was 81.4% (74.8%-86.9%) for ultrasonography and 79.1% (72.2%-84.9%) for both scintigraphy and ultrasonography plus CEUS. The sensitivity difference compared with scintigraphy was 2.3% (-6.8% to 11.4%) for ultrasonography and 0.0% (-9.1% to 9.1%) for ultrasonography plus CEUS, establishing noninferiority for both modalities.
Conclusions And Relevance:
In this cohort study, conventional ultrasonography by an experienced parathyroid surgeon-sonographer was noninferior to scintigraphy and may constitute a valid first-line imaging modality in patients with primary hyperparathyroidism, even without the addition of CEUS. Further imaging should be reserved for cases that are equivocal or nonlocalizing on ultrasonography.
More Related Videos
Related Concept Videos
Imaging Studies II: Ultrasonography
Ultrasonography
During an ultrasonography procedure, a handheld device called...
Imaging Studies V: Intravenous Urography and Retrograde Pyelography
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies III: Computed Tomography