Fitbit Data to Assess Functional Capacity in Patients Before Elective Surgery: Pilot Prospective Observational Study
Alessandra Angelucci1, Massimiliano Greco2,3, Stefano Canali1,4
1Dipartimento di Elettronica, Informazione e Bioingegneria, Politecnico di Milano, Milano, Italy.
Wearable smartwatches can accurately assess patient functional capacity before surgery, correlating well with the 6-Minute Walk Test (6MWT). This technology offers a less intrusive and potentially more accurate method for preoperative assessments.
Area of Science:
- Cardiology
- Geriatrics
- Sports Medicine
- Medical Devices
Background:
- Preoperative assessment is vital for surgical risk stratification, traditionally focusing on functional capacity.
- Wearable devices offer a less invasive, cost-effective, and potentially more accurate approach to functional capacity assessment.
- Smartwatches, trackers, and rings are increasingly accessible for continuous health monitoring.
Purpose of the Study:
- To evaluate the utility of commercial smartwatch data (Fitbit Inspire 2) for preoperative functional capacity assessment.
- To correlate smartwatch-derived metrics with the established 6-Minute Walk Test (6MWT) as the gold standard.
Main Methods:
- Patients underwent the 6-Minute Walk Test (6MWT) during a hospital visit.
- Participants wore a Fitbit Inspire 2 for approximately 7 days post-visit and pre-surgery.
- Resting heart rate and daily step data were extracted; feature engineering created Heart Rate over Steps (HROS) and Non-Exercise Testing Cardiorespiratory Fitness (NEF) metrics.
- All smartwatch-derived metrics were correlated with 6MWT distance.
Main Results:
- The Non-Exercise Testing Cardiorespiratory Fitness index showed the strongest correlation with 6MWT (r=0.68, P<.001).
- Average resting heart rate also correlated significantly (r=-0.39, P=.03).
- Fitbit step count demonstrated a fair correlation with 6MWT (r=0.59, P<.001).
Conclusions:
- Smartwatch data shows strong correlation with the 6MWT, indicating promise for wearable technology in preoperative functional capacity evaluation.
- Future research should address limitations in metric availability, device variability, data accuracy, and accessibility.
- This study serves as a foundational step towards integrating consumer wearables into clinical preoperative assessments.