Measuring downstream supply chain losses due to power disturbances
1National Institute of Standards and Technology, 100 Bureau Drive, Gaithersburg, MD.
Summary
Power disturbances significantly disrupt supply chains, especially in manufacturing, leading to substantial indirect economic losses. Nondurable goods manufacturing experienced the most severe impacts, highlighting a critical gap in power grid reliability investments.
Area of Science:
- Economics
- Industrial Engineering
- Supply Chain Management
Background:
- Power outages in the U.S. disrupt economic activity and cause downstream supply chain disruptions.
- Indirect impacts include losses at firms unable to receive timely supplies due to supplier power disturbances.
Purpose of the Study:
- Examine the impact of power disturbances on the supply chain for manufacturing, durable goods manufacturing, nondurable goods manufacturing, and total private industry.
- Estimate indirect costs of power disturbances using simulation.
Main Methods:
- Measured impact using observations of value added before and after power disturbances.
- Tested four hypotheses related to power disturbance effects.
- Utilized simulation to estimate indirect costs.
Main Results:
- Power disturbances have a statistically significant effect on gross domestic product (value added), particularly in manufacturing.
- Manufacturing accounts for 36.8% of supply chain losses due to power disturbances, despite representing 12.8% of private industry value added.
- Nondurable goods manufacturing was most affected by supply chain power disturbances.
Conclusions:
- Power disturbances significantly impact supply chains across multiple industries.
- A disconnect exists between power grid reliability investors and those experiencing the majority of losses.
- Targeted improvements in power grid reliability are needed to mitigate economic impacts.
Related Concept Videos
Distribution Reliability and Automation
139
Distribution reliability in electrical power systems is critical for ensuring an uninterrupted power supply to consumers at minimal cost. According to IEEE Standard Terms, reliability is the probability that a device will function without failure over a specified time period or amount of usage. For electric power distribution, this translates to maintaining continuous power supply and addressing customer concerns over power outages. Several indices, as defined by IEEE Standard 1366-2012, are...
139
Line Loss
279
The different configurations of source-load connections include wye (star) and delta connections. The relationship between line and phase voltages and currents varies depending on the configuration. When the source is supplying power, it is transmitted through the wires to the load, and during this transmission, some power is absorbed by the wires, leading to line loss.
Line loss impacts power delivery efficiency in a balanced three-phase circuit. The symmetry in such a circuit simplifies the...
Line loss impacts power delivery efficiency in a balanced three-phase circuit. The symmetry in such a circuit simplifies the...
279
Reducing Line Loss
184
In a three-phase circuit, line loss is an indicator of energy dissipated as heat due to the resistance of transmission lines. To address this, incorporating transformers into the system—a step-up transformer at the source and a step-down transformer at the load—is a strategic solution. Two three-phase transformers are introduced to improve this.
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss...
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss...
184
Lossy Lines and Overvoltages
115
Transmission-line series resistance and shunt conductance cause three primary effects: attenuation, distortion, and power losses.
Attenuation
When constant series resistance and shunt conductance are present, voltage and current equations are modified. The propagation constant indicates that voltage and current waves consist of both forward and backward traveling components. These waves attenuate as they propagate, with the attenuation factor related to the resistance and conductance. In a...
Attenuation
When constant series resistance and shunt conductance are present, voltage and current equations are modified. The propagation constant indicates that voltage and current waves consist of both forward and backward traveling components. These waves attenuate as they propagate, with the attenuation factor related to the resistance and conductance. In a...
115
Energy Losses in Transformers
916
In an ideal transformer, it is assumed that there are no energy losses, and, hence, all the power at the primary winding is transferred to the secondary winding. However, in reality, the transformers always have some energy losses, and, hence, the output power obtained at the secondary winding is less than the input power at the primary winding due to energy losses.
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...
916
Power System Three-Phase Short Circuits
121
Determining the subtransient fault current in a power system involves representing transformers by their leakage reactances, transmission lines by their equivalent series reactances, and synchronous machines as constant voltage sources behind their subtransient reactances. In this analysis, certain elements are excluded, such as winding resistances, series resistances, shunt admittances, delta-Y phase shifts, armature resistance, saturation, saliency, non-rotating impedance loads, and small...