Related Experiment Video
Updated: Aug 2, 2025

Quantitative and Temporal Control of Oxygen Microenvironment at the Single Islet Level
Published on: November 17, 2013
MXene-TiO2-based photocatalytic fuel cell with bioresponsive controlled glucose release system: An innovative mode
Zhenli Qiu1, Xianghang Xue1, Yufen Lei1
1Fujian Provincial University Engineering Research Center of Green Materials and Chemical Engineering, College of Materials and Chemical Engineering, Minjiang University, Fuzhou, 350108, PR China; College of Environment & Safety Engineering, Fuzhou University, Fuzhou, 350108, PR China.
Abstract:
Self-powered photocatalytic fuel cell (PFC)-based sensors incorporating bioelement recognition with fuel concentration-dependent output power have been developed for electrochemical analysis, but most involve poor energy conversion efficiency and are unsuitable for routine use. Herein, a self-powered and self-checking PFC bioanalysis platform under visible light for ultrasensitive screening of Ochratoxin A (OTA) was designed. Specifically, the self-powered photocatalytic fuel cell-based sensor was comprised of a photoanode fabricated with MXenes (Ti3C2)-TiO2 and a cathode modified with Prussian blue (PB). To realize the high-performance of OTA detection, mesoporous silica nanoparticles (MSNs) were used as nanocontainers to load glucose, and aptamers were assembled on the surface of MSNs as dual-gated molecules to form signal probes. The reaction of analyte OTA with OTA aptamer was greater than the force between OTA aptamer and MSN, resulting in the release of glucose from MSNs. The released glucose was photo-oxidized by Ti3C2-TiO2 under visible light illumination and used as an electron acceptor to reduce PB, resulting in a high cell output response with a maximum output power (Pmax) of 23.516 μW cm-2. Meanwhile, the electrochromic PB enabled colorimetric detection of OTA with self-checking. The self-powered Ti3C2-TiO2-based PFC with target-recognition cargo release system exhibited superior analytical performance toward OTA in the range of 0.2 ppb-20 ppb and limit of detection (LOD) down to 0.0587 ppb. Additionally, excellent stability, rapid response, and exquisite selectivity for real samples (beer) was acceptable, providing an efficient approach in food safety monitoring.
More Related Videos
05:47Preparation of Polyoxometalate-based Photo-responsive Membranes for the Photo-activation of Manganese Oxide Catalysts
Published on: August 7, 2018
13:42Dry Film Photoresist-based Electrochemical Microfluidic Biosensor Platform: Device Fabrication, On-chip Assay Preparation, and System Operation
Published on: September 19, 2017