Characterization of Aortic Flow Patterns by High-Frame-Rate Blood Speckle Tracking Echocardiography in Children

Massimiliano Cantinotti1,2, Pietro Marchese1,3, Marco Scalese3

  • 1Fondazione G. Monasterio CNR-Regione Toscana Massa, Pisa Italy.

Insights

Blood speckle tracking echocardiography is feasible and reproducible for analyzing aortic flow in healthy children. This technique provides baseline data for assessing pediatric heart conditions.

Area of Science:

  • Pediatric Cardiology
  • Cardiovascular Imaging
  • Hemodynamics

Background:

  • Blood speckle tracking echocardiography (BSTE) enables direct quantification of interventricular and aortic blood flow profiles, particularly in pediatric populations.
  • Current research focuses on demonstrating the feasibility and reproducibility of BSTE in the aortas of healthy children.

Purpose of the Study:

  • To demonstrate the feasibility and reproducibility of blood speckle tracking echocardiography in the aortas of healthy children.
  • To establish baseline vortical flow patterns in the aortic root and ascending aorta.

Main Methods:

  • One hundred healthy children underwent echocardiographic examinations using a Vivid E 95 ultrasound system.
  • Blood speckle tracking was applied to focused, zoomed views of the aortic root and ascending aorta.
  • Vortex characteristics (position, height, width, sphericity index, area) were measured and indexed by body surface area.

Main Results:

  • Vortices were visualized in 25 subjects, predominantly in early diastole (56.0%) and late systole (44.0%).
  • Diastolic vortices had a mean area of 0.27±0.1 cm²/m², while systolic vortices averaged 0.34±0.12 cm²/m².
  • Inter- and intraobserver variability analyses in a subset of 20 patients demonstrated good reproducibility.

Conclusions:

  • Blood speckle tracking echocardiography is a feasible and reproducible method for assessing aortic flow patterns in healthy children.
  • Identified vortical flow patterns in the aortic root and ascending aorta can serve as normative data.
  • This technique holds potential for evaluating aortic flow in pediatric patients with congenital and acquired heart diseases.