Related Experiment Video
Updated: Aug 2, 2025

Drug-Induced Sleep Endoscopy DISE with Target Controlled Infusion TCI and Bispectral Analysis in Obstructive Sleep Apnea
Published on: December 6, 2016
Predictive value of NoSAS questionnaire combined with the modified Mallampati grade for hypoxemia during routine
Nana Li1, Junbei Wu1, Yunhong Lu2
1Department of Anesthesiology, The First Affiliated Hospital of Nanjing Medical University, Nanjing, China.
Background:
The incidence of hypoxemia during painless gastrointestinal endoscopy remains a matter of concem. To date, there is no recognized simple method to predict hypoxemia in digestive endoscopic anesthesia. The NoSAS (neck circumference, obesity, snoring, age, sex) questionnaire, an objective and simple assessment scale used to assess obstructive sleep apnea (OSA), combined with the modified Mallampati grade (MMP), may have certain screening value. This combination may allow anesthesiologists to anticipate, manage, and consequently decrease the occurrence of hypoxemia.
Methods:
This study was a prospective observational trial. The primary endpoint was the incidence of hypoxaemia defined as pulse oxygen saturation (SpO2) < 95% for 10 s. A total of 2207 patients admitted to our hospital for painless gastrointestinal endoscopy were studied. All patients were measured for age, height, weight, body mass index, neck circumference, snoring, MMP, and other parameters. Patients were divided into hypoxemic and non-hypoxemic groups based on the SpO2. The ROC curve was plotted to evaluate the screening value of the NoSAS questionnaire separately and combined with MMP for hypoxemia. The total NoSAS score was evaluated at cut-off points of 8 and 9.
Results:
With a NoSAS score ≥ 8 as the critical value for analysis, the sensitivity for hypoxemia was 58.3%, the specificity was 88.4%, and the area under the ROC was 0.734 (P < 0.001, 95% CI: 0.708-0.759). With a NoSAS score ≥ 9 as a critical value, the sensitivity for hypoxemia was 36.50%, the specificity rose to 96.16%, and the area under the ROC was 0.663 (P < 0.001, 95% CI: 0.639-0.688). With the NoSAS Score combined with MMP for analysis, the sensitivity was 78.4%, the specificity was 84%, and the area under the ROC was 0.859 (P < 0.001, 95%CI:0.834-0.883).
Conclusions:
As a new screening tool, the NoSAS questionnaire is simple, convenient, and useful for screening hypoxemia. This questionnaire, when paired withMMP, is likely to be helpful for the screening of hypoxemia.
More Related Videos
06:28E-Patient Counseling Trial E-PACO: Computer Based Education versus Nurse Counseling for Patients to Prepare for Colonoscopy
Published on: August 1, 2019
04:20Integration of Brain Tissue Saturation Monitoring in Cardiopulmonary Exercise Testing in Patients with Heart Failure
Published on: October 1, 2019
Related Concept Videos
Endoscopic Procedures IV: Sigmoidoscopy and Laproscopy
Sigmoidoscopy
Sigmoidoscopy is a diagnostic procedure that uses a flexible sigmoidoscope equipped with a light source and camera to examine the rectum and sigmoid colon. The procedure involves inserting the tube through the anus...
Endoscopic Procedures I: Esophagogastroduodenoscopy
During an EGD, the endoscope can be used to:
Respiratory Assessment: Purpose and Indications
Objectives and Importance:
The primary goal of respiratory assessment is to evaluate patients at early risk of clinical deterioration. Since respiratory distress often precedes other signs of declining health, breathing patterns and sounds become a...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Assessment of Airway, Skin Color, and Use of Accessory Muscles
Introduction
The initial evaluation of a patient's respiratory system...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...