Split Point Analysis and Uncertainty Quantification of Thermal-Optical Organic/Elemental Carbon Measurements
Published on: September 7, 2019
Comparison of three methods for measuring C0-1 angles and C0-2 angles
Shicai Xu1, Fei Ma1, Chao Tang1
1Department of Orthopaedics, The Affiliated Hospital of Southwest Medical University, No.25 Taipingjie, Lu Zhou, Sichuan, 646000, PR China.
The McGregor line (ML) offers higher reliability for measuring upper cervical angles (C0-1 and C0-2). The Frankfort horizontal line (FHL) is best for assessing the compensatory relationship between upper and lower cervical spine sagittal alignment.
Area of Science:
- Orthopedics
- Radiology
- Spine Surgery
Background:
- The upper and lower cervical spine exhibit a compensatory relationship in sagittal alignment.
- Previous studies show varied methods for measuring upper cervical sagittal parameters.
- This study compares three methods for upper cervical sagittal parameter measurement.
Purpose of the Study:
- To compare the reliability of three reference lines (FHL, FML, ML) for measuring upper cervical sagittal parameters (C0-1 and C0-2 angles).
- To evaluate the correlation between upper and lower cervical sagittal alignment using different measurement methods.
Main Methods:
- Retrospective analysis of 263 lateral cervical radiographs.
- Measurement of C0-1 and C0-2 angles using Frankfort horizontal line (FHL), foramen magnum line (FML), and McGregor line (ML).
- Intraclass correlation (ICC) for reliability; Pearson's correlation for parameter relationships.
Main Results:
- McGregor line (ML) demonstrated higher interobserver and intraobserver ICC values for C0-1 and C0-2 angles compared to FML and FHL.
- All measured upper cervical angles showed a negative correlation with the C2-7 angle (lower cervical alignment).
- Upper sagittal parameters measured by FHL showed the strongest correlation with C2-7 angle, with correlations increasing with age.
Conclusions:
- The McGregor line (ML) provides a more reliable method for measuring C0-1 and C0-2 angles.
- The Frankfort horizontal line (FHL) is more suitable for evaluating the compensatory mechanism between the upper and lower cervical spine.
Related Concept Videos
2D NMR: Overview of Homonuclear Correlation Techniques
COSY90 is the standard two-dimensional (2D) COSY experiment that...
2D NMR: Homonuclear Correlation Spectroscopy (COSY)
2D NMR: Overview of Heteronuclear Correlation Techniques
Spin–Spin Coupling: Two-Bond Coupling (Geminal Coupling)
The central atom need not be NMR-active because its electrons are affected by the electron polarization of the spin-active atoms. However, spin information is transmitted less effectively than in one-bond coupling, and 2J values are usually weaker than 1J values. The energy of...
¹³C NMR: ¹H–¹³C Decoupling
A broadband decoupling technique is used to simplify these complex, sometimes overlapping, signals. Broadband decoupling relies on a...
Spin–Spin Coupling: Three-Bond Coupling (Vicinal Coupling)
The extent of coupling depends on the C‑C bond length, the two H‑C‑C angles, any electron-withdrawing substituents, and the dihedral angle between the...