Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Fatty acid metabolism and the oxidative stress response support bacterial predation.

Proceedings of the National Academy of Sciences of the United States of America·2025
Same author

Thin adhesive oil films lead to anomalously stable mixtures of water in oil.

Science (New York, N.Y.)·2024
Same author

Encapsulation of Cells in a Collagen Matrix Surrounded by an Alginate Hydrogel Shell for 3D Cell Culture.

ACS biomaterials science & engineering·2022
Same author

Patterning of a Drying Emulsion Film.

Langmuir : the ACS journal of surfaces and colloids·2021
Same author

Author Correction: Dynamic single-cell phenotyping of immune cells using the microfluidic platform DropMap.

Nature protocols·2021
Same author

Deep phenotypic characterization of immunization-induced antibacterial IgG repertoires in mice using a single-antibody bioassay.

Communications biology·2020

Related Experiment Video

Updated: Aug 2, 2025

Fluorescence detection methods for microfluidic droplet platforms
14:16

Fluorescence detection methods for microfluidic droplet platforms

Published on: December 10, 2011

22.3K

Droplet-based microfluidic platform for viscosity measurement over extended concentration range.

Paul Cochard-Marchewka1, Nicolas Bremond1, Jean Baudry1

  • 1Laboratoire Colloïdes et Matériaux Divisés, Institut Chimie, Biologie, Innovation, UMR 8231, ESPCI Paris, CNRS, Université Paris Sciences et Lettres, 75005 Paris, France. paul.cochard-marchewka@espci.psl.eu.

Lab on a Chip
|April 18, 2023
PubMed
Summary

This study introduces a microfluidic device for precise viscosity measurements of concentrated protein solutions, significantly reducing sample volume. The novel approach enables detailed rheological analysis with minimal sample consumption, vital for biopharmaceutical development.

More Related Videos

Pneumatically Driven Microfluidic Platform for Micro-Particle Concentration
08:43

Pneumatically Driven Microfluidic Platform for Micro-Particle Concentration

Published on: February 1, 2022

2.5K
Capillary-based Centrifugal Microfluidic Device for Size-controllable Formation of Monodisperse Microdroplets
08:20

Capillary-based Centrifugal Microfluidic Device for Size-controllable Formation of Monodisperse Microdroplets

Published on: February 22, 2016

10.4K

Related Experiment Videos

Last Updated: Aug 2, 2025

Fluorescence detection methods for microfluidic droplet platforms
14:16

Fluorescence detection methods for microfluidic droplet platforms

Published on: December 10, 2011

22.3K
Pneumatically Driven Microfluidic Platform for Micro-Particle Concentration
08:43

Pneumatically Driven Microfluidic Platform for Micro-Particle Concentration

Published on: February 1, 2022

2.5K
Capillary-based Centrifugal Microfluidic Device for Size-controllable Formation of Monodisperse Microdroplets
08:20

Capillary-based Centrifugal Microfluidic Device for Size-controllable Formation of Monodisperse Microdroplets

Published on: February 22, 2016

10.4K

Area of Science:

  • Biophysics
  • Materials Science
  • Chemical Engineering

Background:

  • Concentrated protein solutions are vital for macromolecular crowding dynamics and protein therapeutic formulation.
  • Conventional rheological methods require large sample volumes, limiting studies due to protein cost and scarcity.
  • A need exists for precise, low-volume viscosity measurement tools for concentrated protein solutions.

Purpose of the Study:

  • To develop a microfluidic microsystem for accurate viscosity measurements of concentrated aqueous solutions.
  • To enable rheological studies with significantly reduced sample consumption.
  • To facilitate the formulation and understanding of protein therapeutics.

Main Methods:

  • Integration of microfluidics and particle-tracking microrheology in a PDMS chip.
  • In situ production, storage, and monitoring of nanoliter water-in-oil droplets.
  • Sample concentration via water pervaporation, increasing concentration up to 150x.
  • Viscosity measurement within individual droplets using fluorescent probes.

Main Results:

  • The microsystem precisely measures viscosity across an extended concentration range in a single experiment.
  • Methodology validated using sucrose solutions.
  • Successful rheological studies of two model proteins with only 1 μL of diluted solution.
  • Demonstrated significant reduction in sample consumption for biopharmaceutical studies.

Conclusions:

  • The developed microfluidic microrheology approach offers a precise and robust method for studying concentrated protein solutions.
  • This technique significantly reduces sample volume requirements, addressing limitations of conventional methods.
  • The approach is highly viable for biopharmaceutical research and development, enabling detailed rheological characterization.