Related Experiment Video
Updated: Aug 2, 2025

An Optimized Protocol for Electrophoretic Mobility Shift Assay Using Infrared Fluorescent Dye-labeled Oligonucleotides
Published on: November 29, 2016
Theoretical and computational analysis of the electrophoretic polymer mobility inversion induced by charge
Xiang Yang1, Sahin Buyukdagli2, Alberto Scacchi1,3
1Department of Applied Physics, Aalto University, P. O. Box 11000, FI-00076 Aalto, Finland.
Abstract:
Electrophoretic (EP) mobility reversal is commonly observed for strongly charged macromolecules in multivalent salt solutions. This curious effect takes place, e.g., when a charged polymer, such as DNA, adsorbs excess counterions so that the counterion-dressed surface charge reverses its sign, leading to the inversion of the polymer drift driven by an external electric field. In order to characterize this seemingly counterintuitive phenomenon that cannot be captured by electrostatic mean-field theories, we adapt here a previously developed strong-coupling-dressed Poisson-Boltzmann approach to the cylindrical geometry of the polyelectrolyte-salt system. Within the framework of this formalism, we derive an analytical polymer mobility formula dressed by charge correlations. In qualitative agreement with polymer transport experiments, this mobility formula predicts that the increment of the monovalent salt, the decrease of the multivalent counterion valency, and the increase of the dielectric permittivity of the background solvent suppress charge correlations and increase the multivalent bulk counterion concentration required for EP mobility reversal. These results are corroborated by coarse-grained molecular dynamics simulations showing how multivalent counterions induce mobility inversion at dilute concentrations and suppress the inversion effect at large concentrations. This re-entrant behavior, previously observed in the aggregation of like-charged polymer solutions, calls for verification by polymer transport experiments.
Related Concept Videos
Electrophoresis: Overview
There...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Two-dimensional Gel Electrophoresis
The first dimension separation uses the isoelectric focusing or IEF technique performed on immobilized pH gradient (IPG) strips that separate proteins according to their isoelectric points.
Biological samples, such...
Induced Electric Dipoles
Since the absolute value of potential energy holds no physical meaning, its zero value can be chosen as per...
Potential Due to a Polarized Object
Ion-Exchange Chromatography

