Accuracy of Cardiac Output Measured by Fourth-Generation FloTrac and LiDCOrapid, and Their Characteristics Regarding
Yusuke Takei1, Michio Kumagai1, Manami Suzuki1
1Department of Anesthesiology and Perioperative Medicine, Tohoku University Graduate School of Medicine, Sendai, Japan.
Objectives:
The clinical use of less-invasive devices that calculate the cardiac output from arterial pressure waveform is increasing. The authors aimed to evaluate the accuracy and characteristics of the systemic vascular resistance index (SVRI) of the cardiac index measured by 2 less-invasive devices, fourth-generation FloTrac (CIFT) and LiDCOrapid (CILR), compared with the intermittent thermodilution technique, using a pulmonary artery catheter (CITD).
Design:
This was a prospective observational study.
Setting:
This study was conducted at a single university hospital.
Participants:
Twenty-nine adult patients undergoing elective cardiac surgery.
Interventions:
Elective cardiac surgery was used as an intervention.
Measurements And Main Results:
Hemodynamic parameters, CIFT, CILR, and CITD, were measured after the induction of general anesthesia, at the start of cardiopulmonary bypass, after completion of weaning from cardiopulmonary bypass, 30 minutes after weaning, and at sternal closure (135 measurements in total). The CIFT and CILR had moderate correlations with CITD (r = 0.62 and 0.58, respectively). Compared with CITD, CIFT, and CILR had a bias of -0.73 and -0.61 L/min/m2, limit of agreement of -2.14-to-0.68 L/min/m2 and -2.42-to-1.20 L/min/m2, and percentage error of 39.9% and 51.2%, respectively. Subgroup analysis for evaluating SVRI characteristics showed that the percentage errors of CIFT and CILR were 33.9% and 54.5% in low SVRI (<1,200 dyne×s/cm5/m), 37.6% and 47.9% in moderate SVRI (1,200-1,800 dyne×s/cm5/m), 49.3% and 50.6% in high SVRI (>1,800 dyne·s/cm5/m2), respectively.
Conclusions:
The accuracy of CIFT or CILR was not clinically acceptable for cardiac surgery. Fourth-generation FloTrac was unreliable in high SVRI. LiDCOrapid was inaccurate across a broad range of SVRI, and minimally affected by SVRI.
More Related Videos
05:07Author Spotlight: Improved Localization and Monitoring of Coronary Flow Reserve Using Modified PLAX View in Mice
Published on: August 25, 2023
04:48Noninvasive Determination of Vortex Formation Time Using Transesophageal Echocardiography During Cardiac Surgery
Published on: November 28, 2018
Related Concept Videos
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac...
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart...