Related Experiment Video
Updated: Aug 2, 2025

In Situ Surface Temperature Measurement in a Conveyor Belt Furnace via Inline Infrared Thermography
Published on: May 30, 2020
Can retro-reflective materials replace diffuse highly reflective materials for urban buildings' wall to improve
Jihui Yuan1,2, Yasuhiro Shimazaki1, Ruijun Zhang3
1Dept. of Architecture and Civil Eng., Graduate School of Eng., Toyohashi University of Technology, Aichi, Japan.
Abstract:
In recent years, there have been numerous studies on the application of retroreflective (RR) materials to exterior building walls to relieve the urban heat island (UHI) phenomenon and save building energy consumption instead of diffuse highly reflective (DHR) materials. Experimental measurements were undertaken to investigate the impact of applying DHR and RR materials to building exterior walls on the outdoor thermal environment. DHR and RR walls were tested with three canyon aspect ratios ( / ) of 0.5, 1.0, and 1.5, respectively, with seven environmental indexes recorded and compared, including air temperature ( ), relative humidity ( ), sol-air temperature ( ), operative temperature ( ), standard effective temperature ( ), change in operative temperature ( ), and real-time solar reflectance ( ). The results show that the RR wall is more effective in improving the outdoor thermal environment, where decreased by 4.5 °C, decreased by 0.5 °C, and decreased by 1.2 °C, on average, while it can also improve the real-time solar reflectance ( ) by 12% on average compared to the DHR wall. Moreover, it gets more effective in scenarios with a higher canyon aspect ratio.
More Related Videos
07:37TiO2-coated Hollow Glass Microspheres with Superhydrophobic and High IR-reflective Properties Synthesized by a Soft-chemistry Method
Published on: April 26, 2017
07:48Artificial Thermal Ageing of Polyester Reinforced and Polyvinyl Chloride Coated Technical Fabric
Published on: January 29, 2020
Related Concept Videos
Thermal Insulation in Masonry Walls
External insulation can be applied using an Exterior Insulation and Finish System (EIFS), which involves affixing panels of plastic foam to the wall and covering them with a polymeric stucco reinforced with glass fiber mesh....
Conduction, Convection and Radiation: Problem Solving
In order to solve a problem related to heat transfer, first of all, the situation needs to be examined to determine the type of heat transfer involved. This could...
Design Example: Sustainability in Concrete Building
There are multiple approaches to achieve sustainability in a commercial concrete building. For instance, construct a concrete parking area under the building, utilizing pervious concrete paver blocks in open areas to facilitate rainwater collection through an underground...
Masonry Curtain Walls
Cavity Drainage and Flashings in Masonry walls
Weep holes, strategically placed at the base of the cavity, are critical for draining accumulated water. These openings are created by leaving head...
Radiation: Applications
The average...