Purpose Of Review:
The aim of this study was to review the role of haemodynamic monitoring in the perioperative setting, highlighting who are the patients who most benefit, to describe the type of devices, to analyse the scientific evidence and to suggest algorithms of haemodynamic care in high-risk surgical patients.
Recent Findings:
In the last 50 years, many advances have contributed to better understand cardiovascular physiology at bedside, and haemodynamic monitoring has moved from invasive methods to minimally invasive and noninvasive devices. Randomized clinical trials have shown benefits of perioperative haemodynamic therapy to improve outcomes in high-risk surgical patients. A multimodal approach is purposed in the perioperative setting to optimize haemodynamic parameters, involving clinical analysis at bedside, the use of dynamic tests for fluid responsiveness and integration of variables, including cardiac output, systolic volume, tissue oxygen markers and echocardiographic measures.
Summary:
In this review, we summarize the benefits of haemodynamic monitoring, the type of devices with advantages and disadvantages, the scientific evidence supporting perioperative haemodynamic therapy, and we suggest a multimodal approach to improve patients' care.
More Related Videos
Related Concept Videos
Cardiomyopathy VII: Pre and Post Operative Nursing Management
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Aneurysm IV: Nursing Management
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.