Related Experiment Video
Updated: Aug 2, 2025

Investigating Long-Distance Transport of Perfluoroalkyl Acids in Wheat via a Split-Root Exposure Technique
Published on: September 28, 2022
Particle and gas phase sampling of PCDD/Fs and dl-PCBs by activated carbon fiber and GC/MS analysis
Marina Cerasa1, Ettore Guerriero1, Catia Balducci1
1Italian National Research Council, Institute of Atmospheric Pollution Research, Area Della Ricerca Di Roma 1, 00010, Montelibretti (RM), Italy.
Abstract:
Polychlorodibenzo-p-dioxins (PCDDs), polychlorodibenzofurans (PCDFs), and polychlorobiphenyls (PCBs) are semi-volatile compounds and can be partitioned in the atmosphere between the gas and particulate phase, due to their physicochemical properties. For this reason, the reference standard methods for air sampling include a quartz fiber filter (QFF) for the particulate and a polyurethane foam (PUF) cartridge for the vapor phase, and it is the classical and most popular sampling method in the air. Despite the presence of the two adsorbing media, this method cannot be used for the study of the gas-particulate distribution, but only for a total quantification. This study presents the results and the performance aim to validate an activated carbon fiber (ACF) filter for the sampling of PCDD/Fs and dioxin-like PCBs (dl-PCBs) using laboratory and field tests. The specificity, precision, and accuracy of the ACF in relation to the QFF + PUF were evaluated through the isotopic dilution technique, the recovery rates, and the standard deviations. Then the ACF performance was assessed on real samples, in a naturally contaminated area, through parallel sampling with the reference method (QFF + PUF). The QA/QC was defined according to the standard methods ISO 16000-13 and -14 and EPA TO4A and 9A. Data confirmed that ACF meets the requirements for the quantification of native POPs compounds in atmospheric and indoor samples. In addition, ACF provided accuracy and precision comparable to those offered by standard reference methods using QFF + PUF, but with significant savings in terms of time and costs.
More Related Videos
08:12Characterization, Quantification and Compound-specific Isotopic Analysis of Pyrogenic Carbon Using Benzene Polycarboxylic Acids BPCA
Published on: May 16, 2016
09:04Identifying Per- and Polyfluorinated Chemical Species with a Combined Targeted and Non-Targeted-Screening High-Resolution Mass Spectrometry Workflow
Published on: April 18, 2019
Related Concept Videos
Gas Chromatography: Types of Detectors-II
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Supercritical Fluid Chromatography
SFC utilizes a supercritical fluid mobile phase,...