Background And Purpose:
Wrong-level spinal surgery, especially in the thoracic spine, remains a challenge for a variety of reasons related to visualization, such as osteopenia, large body habitus, severe kyphosis, radiographic misinterpretation, or anatomic variation. Preoperative fiducial marker placement performed in a dedicated imaging suite has been proposed to facilitate identification of thoracic spine vertebral levels. In this current study, we report our experience using image-guided percutaneous gold fiducial marker placement to enhance the accuracy and safety of thoracic spinal surgical procedures.
Materials And Methods:
A retrospective review was performed of all fluoroscopy- or CT-guided gold fiducial markers placed at our institution between January 3, 2019, and March 16, 2022. A chart review of 179 patients was performed detailing the procedural approach and clinical information. In addition, the method of gold fiducial marker placement (fluoroscopy/CT), procedure duration, spinal level of the gold fiducial marker, radiation dose, fluoroscopy time, surgery date, and complications (including whether wrong-level surgery occurred) were recorded.
Results:
A total of 179 patients (104 female) underwent gold fiducial marker placement. The mean age was 57 years (range, 12-96 years). Fiducial marker placement was performed by 13 different neuroradiologists. All placements were technically successful without complications. All 179 (100%) operations were performed at the correct level. Most fiducial markers (143) were placed with fluoroscopy with the most common location at T6-T8. The most common location for placement in CT was at T3 and T4.
Conclusions:
All operations guided with gold fiducial markers were performed at the correct level. There were no complications of fiducial marker placement.