Comparative Study Between Non-Diffractive Extended Depth of Focus and Monofocal Intraocular Lenses
Rom Kandavel1, Michael Colvard1, Justin Dredge1
1Colvard-Kandavel Eye Center, Encino, CA, 91316, USA.
Purpose:
To evaluate the visual acuity and quality of vision in bilaterally implanted ZCBOO/ZCTx monofocal (Johnson & Johnson Vision) intraocular lens (IOL) and bilaterally implanted DATx15 extended depth of focus (EDOF) IOL (Alcon Vision, LLC).
Methods:
A single site, non-interventional study comparing ZCBOO/ZCTx monofocal IOL patients implanted with DATx15 IOL toric or non-toric versions in both eyes. A total of 30 patients (60 eyes) completed the study in the monofocal group, 32 (64 eyes) in the EDOF group, and all were targeted for emmetropia. Binocular uncorrected distance, intermediate (66cm), and near (40cm) visual acuities and distance corrected distance, intermediate (66cm) and near (40cm) visual acuities were assessed. Binocular distance corrected defocus curve testing was from -3.5 D to +3 D. Patient reported visual disturbances (QUVID) and IOL satisfaction (IOLSAT) questionnaires were administered.
Results:
The DATx15 group mean uncorrected visual acuity was 0.15 ± 0.10 logMAR at 66cm and 0.36 ± 0.14 logMAR at 40cm, compared to 0.24 ± 0.15 logMAR and 0.59 ± 0.17 logMAR respectively for the ZCBOO/ZCTx group. The DATx15 group (23 respondents, 74%) also reported significantly more spectacle independence at near with the IOLSAT (p < 0.01), compared to the ZCBOO/ZCTx group (13 respondents, 43%). Glare, halos, starbursts, and blur reported on the QUVID questionnaire were similar in the two groups.
Conclusion:
The DATx15 group had improved near and intermediate vision and increased spectacle independence compared to the ZCBOO/ZCTx group.
More Related Videos
06:55Scanning Light Scattering Profiler SLPS Based Methodology to Quantitatively Evaluate Forward and Backward Light Scattering from Intraocular Lenses
Published on: June 6, 2017
07:12Spatio-Temporal In Vivo Imaging of Ocular Drug Delivery Systems using Fiberoptic Confocal Laser Microendoscopy
Published on: September 27, 2021
Related Concept Videos
Focusing of Light in the Eye
Confocal Fluorescence Microscopy
Imaging Biological Samples with Optical Microscopy
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...