Related Experiment Video
Updated: Aug 2, 2025

Two-way Valorization of Blast Furnace Slag: Synthesis of Precipitated Calcium Carbonate and Zeolitic Heavy Metal Adsorbent
Published on: February 21, 2017
Nonlinear regression for treating adsorption isotherm data to characterize new sorbents: Advantages over
1Instituto Federal de Educação Ciência e Tecnologia de Mato Grosso, Cuiabá, Brazil.
Abstract:
This paper demonstrates that determining adsorption capacity and affinity through data fitting of adsorption isotherms by nonlinear regression (NLR) is more accurate than linearized Langmuir equations. Linearization errors and the subjective choice of data points used to apply the linear regression analysis may deviate the fitted adsorption parameters (constants and adsorption capacities) from the expected values. The deviation magnitude increases for heterogeneous sorbents such as environmental particles and molecularly imprinted polymers, which adsorb by more than one sorption mechanism or adsorption sites of diverse chemical natures. For instance, Lineweaver-Burk linearization of isotherms simulated considering the presence of two adsorption sites (distinct adsorption energies) provides excellent linear regression fittings but for only one kind of adsorption site. Contrary, Scatchard and Eadie-Hoffsiee's equations indicate the presence of more than one kind of adsorption site, but if the difference between the adsorption constants is not significant, the choice of points used to perform the computation becomes subjective. On the contrary, NLR analysis considers all the adsorption points (experimental or simulated), providing objective criteria to define if more than one kind of site or retention mechanism rules the adsorbed amounts of analyte. The fitted constants have smaller deviations from the expected values than those obtained by linearization. In addition to the simulated data, the enhanced robustness of the NLR was demonstrated in the determination of the adsorption capacity and adsorption affinity of a humic acid sample towards Cu2+ at different pH.
More Related Videos
09:43Study of Short Peptide Adsorption on Solution Dispersed Inorganic Nanoparticles Using Depletion Method
Published on: April 11, 2020
11:38In situ FTIR Spectroscopy as a Tool for Investigation of Gas/Solid Interaction: Water-Enhanced CO2 Adsorption in UiO-66 Metal-Organic Framework
Published on: February 1, 2020
Related Concept Videos
Analyte Adsorption and Distribution
One-Compartment Open Model: Wagner-Nelson and Loo Riegelman Method for ka Estimation
On...
Calibration Curves: Linear Least Squares
For data that follow a straight line, the standard method for fitting is the linear...
Parameters Affecting Nonlinear Elimination: Zero-Order Input, First-Order Absorption and Two-Compartment Model
When a drug is administered through a constant intravenous infusion and eliminated via nonlinear pharmacokinetics, it follows zero-order input. For example, oral drugs undergo first-order absorption upon administration and are eliminated through nonlinear pharmacokinetics.
In the case of subcutaneously administered drugs,...
Chromatography: Introduction
The phase in which the compounds linger or on which the compounds adsorb is called the stationary phase, whereas the mobile phase is the solvent that carries the solutes to be analyzed. In traditional column chromatography, the mixture flows through the stationary phase, and the compounds partition between the stationary and mobile phases...
Regression Analysis
In regression analysis, a regression equation is determined based on the line of best fit– a line that best fits the data points plotted in a graph. This line is also called the regression line. The algebraic equation for the regression line is called the regression equation. It is represented as: