Comparison and agreement between device-estimated and self-reported sleep periods in adults
Laura Nauha1,2,3, Vahid Farrahi1, Heidi Jurvelin2,4
1Research Unit of Health Sciences and Technology, University of Oulu, Oulu, Finland.
Objectives:
Discriminating sleep period from accelerometer data remains a challenge despite many studies have adapted 24-h measurement protocols. We aimed to compare and examine the agreement among device-estimated and self-reported bedtime, wake-up time, and sleep periods in a sample of adults.
Materials And Methods:
Participants (108 adults, 61 females) with an average age of 33.1 (SD 0.4) were asked to wear two wearable devices (Polar Active and Ōura ring) simultaneously and record their bedtime and wake up time using a sleep diary. Sleep periods from Polar Active were detected using an in-lab algorithm, which is openly available. Sleep periods from Ōura ring were generated by commercial Ōura system. Scatter plots, Bland-Altman plots, and intraclass correlation coefficients (ICCs) were used to evaluate the agreement between the methods.
Results:
Intraclass correlation coefficient values were above 0.81 for bedtimes and wake-up times between the three methods. In the estimation of sleep period, ICCs ranged from 0.67 (Polar Active vs. sleep diary) to 0.76 (Polar Active vs. Ōura ring). Average difference between Polar Active and Ōura ring was -1.8 min for bedtimes and -2.6 min for wake-up times. Corresponding values between Polar Active and sleep diary were -5.4 and -18.9 min, and between Ōura ring and sleep diary -3.6 min and -16.2 min, respectively.
Conclusion:
Results showed a high agreement between Polar Active activity monitor and Ōura ring for sleep period estimation. There was a moderate agreement between self-report and the two devices in estimating bedtime and wake-up time. These findings suggest that potentially wearable devices can be interchangeably used to detect sleep period, but their accuracy remains limited.Key MessagesEstimation of sleep period from different devices could be comparable.Difference between sleep periods from monitors and sleep diary are under 20 min.Device-based estimation of sleep period is encouraged in population-based studies.
Related Concept Videos
Sleep-Wake Cycles
NREM Sleep
NREM sleep comprises four progressive stages that seamlessly merge:
Blind Procedures
Stages of Sleep
Before sleep begins, in wakefulness, the brain exhibits primarily beta waves, which are high in frequency and low in amplitude, indicating alertness...
Substance Use Disorders Affecting Sleep
Understanding the concepts of physical dependence,...
Insufficient Sleep and Sleep Deprivation
Sleep deprivation is a more severe form of sleep loss...
Understanding Sleep
The circadian rhythm, a nearly 24-hour cycle, is deeply influenced by environmental light cues. Light exposure directly affects the hypothalamus, which in turn regulates...


