Related Experiment Video
Updated: Aug 2, 2025

Applicability Analysis of Assessment Methods for Morphological Parameters of Corroded Steel Bars
Published on: November 1, 2018
Evaluation of Mechanically-Assisted Crevice Corrosion of Different Modular Dual Mobility Constructs
John R Steele1, Aarti A Shenoy2, Ashley Pekmezian2
1Adult Reconstruction and Joint Replacement Division, Hospital for Special Surgery, New York, New York; Towson Orthopaedic Associates, Orthopaedic Institute at St. Joseph's Medical Center, Towson, Maryland.
Background:
Modular dual mobility (MDM) acetabular component use is rising in total hip arthroplasty. However, concern of mechanically assisted crevice corrosion (MACC) at the shell-liner interface remains. We investigated shell-liner corrosion using retrieval analyses and corrosion chamber testing.
Methods:
We analyzed fretting and corrosion on 10 matched pairs of 2 commercial MDM constructs (MDM1 and MDM2). Also, pristine pairs of Ti6Al4V shells and CoCrMo liners from 3 commercial dual mobility systems (MDM1, MDM2, and MDM3) were tested in vitro to model MACC performance. Three pairs of each were placed into an electrochemical chamber with stepwise increasing cyclic compression loads while measuring currents generated at the shell-liner taper. Onset fretting loads and fretting currents were calculated.
Results:
Corrosion damage scores on retrieved components were low but higher in the MDM2 to MDM1 liners (P = .006), specifically outside the taper region (P = .00003). Fretting currents were higher in the MDM2 than in MDM1 or MDM3 (P = .011). Onset loads were also higher in the MDM2 (P = .001).
Conclusion:
Among retrieved liners, MDM2 tapers seem prone to non-mechanical corrosion modes. Higher onset loads and fretting currents in MDM2 tapers indicate greater MACC resistance but higher severity once corrosion begins. Differences among the devices were likely due to taper design and surface finish. Currents in all 3 were <5 μA, much lower than those observed with head-neck tapers. Our findings suggest that, among the types of corrosion observed in these MDM designs, mechanically driven corrosion may not be the most significant.
Related Concept Videos
Corrosion of Reinforcement
However, over time and under certain conditions like carbonation, chloride ingress, and cracking this protective state can be compromised. Steel has areas with...
Mortar Joint Deterioration in Masonry
The...
Abrasion Resistance of Concrete
One such test is the revolving disc test, where three plates...
Factors Affecting Creep
Further, the water/cement ratio is critical, as a lower ratio increases concrete strength, thus reducing creep. The strength of the...
Design Consideration
The factor of safety is another key...
Mortar Properties