Risk factor analysis of bone cement leakage for polymethylmethacrylate-augmented cannulated pedicle screw fixation in
Yao-Yao Liu1, Jun Xiao2, Lei He3
1Department of Spine Surgery, Daping Hospital, Army Medical Center of PLA, Chongqing, 400042, PR China.
Objective:
To investigate the risk factors of cement leakage (CL) for polymethylmethacrylate-augmented cannulated pedicle screw (CPS) in spinal degenerative diseases and provided technical guidance for clinical surgery.
Methods:
This study enrolled 276 patients with spinal degenerative disease and osteoporosis who were augmented using CPSs (835 screws in total) from May 2011 to June 2018 in our hospital. The patients' age, sex, bone mineral density (BMD), diagnosis, augmented positions, number of CPS implanted, and CL during surgery were recorded. CL was observed by postoperative computed tomography (CT) and was classified by Yeom typing.
Results:
A total of 74 (74/835, 8.9%) CPSs in 64 patients leaked (64/276, 23.2%). CL was significantly correlated with the number and position of screws (P < 0.05), but not with sex, age, and BMD (P > 0.05). The position, number of CPSs, fracture, degenerative scoliosis, ankylosing spondylitis, and revision surgery were risk factors for CL (P < 0.05). Augmentation of the thoracic vertebral body, fracture, and ankylosing spondylitis were independent risk factors for Type S. Augmentation of the lumbar vertebral body, lumbar disc herniation, and lumbar spondylolisthesis were independent risk factors for Type B (P < 0.05).
Conclusions:
CL has a high incidence in clinical practice. High-risk factors for leakage should be addressed to avoid serious complications. Particularly, it is necessary to develop alternative solutions once CPSs can't be used in surgery caused by CL.