Related Experiment Video
Updated: Aug 1, 2025

Manufacture of a Multi-Purpose Low-Cost Animal Bench-Model for Teaching Tracheostomy
Published on: May 18, 2019
Stress Testing the Cardiac Catheterization Laboratory: A Novel Use of In Situ Simulation to Identify and Mitigate
Farrukh Nadeem Jafri1, Rachel C Santana Felipes, Dimitrios Bliagos
1From the White Plains Hospital (F.N.J., R.S, D.B, R.T, A.A, D.E, D.M, K.E, J.C, G.A, H.P), White Plains, NY; SUNY Downstate Medical Center (S.B), Brooklyn, NY; and Brigham and Women's Hospital (A.K), Boston, MA.
Introduction:
Although uncommon, cardiac arrests in the cardiac catheterization laboratory (CCL) are often catastrophic and likely to increase with rising case complexity. In situ simulation (ISS) has been used to identify latent safety threats (LSTs) in inpatient units but has not yet been studied in the CCL.
Methods:
Three Plan-Do-Study-Act (PDSA) cycles leveraging ISS were conducted focused on acute airway management. Data collected through debriefs focused on (1) airway management, (2) equipment availability, and (3) interdepartmental communication. The LSTs were subcategorized and plotted on the Survey Analysis for Evaluating Risk (SAFER)-Matrix. A SAFER score was calculated based on quantifying the likelihood of harm, scope, and the number of times a threat was identified during simulation. Time to definitive airway was collected as a secondary measure. Interventions were developed using cause and effect and driver diagrams between PDSA cycles.
Results:
Eleven total simulations through 3 PDSA cycles were conducted between January and December 2021 (5 in PDSA 1, 4 in PDSA 2, and 2 in PDSA 3). One hundred one LSTs were identified with 14 total subcategories. The mean SAFER score decreased from 5.37 in PDSA 1, to 2.96 in PDSA 2, and to 1.00 in PDSA 3. Bivariate regression analysis showed a decrease in SAFER score of 2.19 for every PDSA cycle ( P = 0.011). Ordinary least squares regression had a decrease of 1.65 in airway-related threats every PDSA cycle ( P < 0.01) as well as an increase in intubation time of 35.0 seconds for every 1-unit increase in communication threat identified ( P = 0.037).
Conclusions:
This study successfully leveraged ISS and existing quality improvement initiatives in the CCL, resulting in a decrease in airway-related threats as measured through simulation.
Related Concept Videos
Cardiopulmonary Resuscitation II: ACLS Airway Management
Acute Coronary Syndrome III: Diagnostic Studies
Cardiac Catheterization III: Left Heart Catheterization
Cardiac Catheterization I: Pre-Procedure Overview
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Acute Coronary Syndrome V: Nursing Management