Related Experiment Video
Updated: Aug 1, 2025

Assessment of the Efficacy of An Osteopathic Treatment in Infants with Biomechanical Impairments to Suckling
Published on: February 5, 2019
Validation of subjective manual palpation using objective physiological recordings of the cranial rhythmic impulse
Holger Pelz1, Gero Müller2, Micha Keller3,4
1Deutsche Gesellschaft für Osteopathische Medizin e.V., St.-Petri-Platz 5, 21614, Buxtehude, Germany.
Abstract:
Intermediate (IM) band physiology in skin blood flow exhibits parallels with the primary respiratory mechanism (PRM) or cranial rhythmic impulse (CRI), controversial concepts of osteopathy in the cranial field (OCF). Owing to inconsistent manual palpation results, validity of evidence of PRM/CRI activity has been questionable. We therefore tried to validate manual palpation combining instrumented tracking and algorithmic objectivation of frequencies, amplitudes, and phases. Using a standard OCF intervention, cranial vault hold (CVH), two OCF experts palpated and digitally marked CRI frequencies in 25 healthy adults. Autonomic nervous system (ANS) activity in low frequency (LF) and IM band in photoplethysmographic (PPG) forehead skin recordings was probed with momentary frequency of highest amplitude (MFHA) and wavelet amplitude spectra (WAS) in examiners and participants. Palpation errors and frequency expectation bias during CVH were analyzed for phases of MFHA and CRI. Palpated CRI frequencies (0.05-0.08 Hz) correlated highly with mean MFHA frequencies with 1:1 ratio in 77% of participants (LF-responders; 0.072 Hz) and with 2:1 ratio in 23% of participants (IM-responders; 0.147 Hz). WAS analysis in both groups revealed integer number (harmonic) waves in (very) low and IM bands in > 98% of palpated intervals. Phase analyses in participants and examiners suggested synchronization between MFHA and CRI in a subset of LF-responders. IM band physiology in forehead PPG may offer a sensible physiological correlate of palpated CRI activity. Possible coordination or synchronization effects with additional physiological signals and between examiners and participants should be investigated in future studies.
Related Concept Videos
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Assessment of apical pulse
Assessing the apical pulse is a critical nursing procedure, particularly indicated for:
Physical Assessment of the Respiratory Tract II: Palpation
Thoracic Palpation
Thoracic palpation detects tenderness, masses, lesions, respiratory excursions, and vocal fremitus. The nurse assesses...
Assessment of the Abdomen III: Palpation
Assessment of the Abdomen II: Percussion
Percussion
Percussion is an essential...

