Related Experiment Video
Updated: Aug 1, 2025

Ovarian Cancer Detection Using Photoacoustic Flow Cytometry
Published on: January 17, 2020
Detection of clot formation & lysis In-Vitro using high frequency photoacoustic imaging & frequency analysis
Filip J Bodera1,2,3, Mark J McVey1,3,4, Krishnan Sathiyamoorthy1,2
1Department of Physics, Toronto Metropolitan University, Toronto, Canada.
Clotting is a physiological process that prevents blood loss after injury. An imbalance in clotting factors can lead to lethal consequences such as exsanguination or inappropriate thrombosis. Clinical methods to monitor clotting and fibrinolysis typically measure the viscoelasticity of whole blood or optical density of plasma over time. Though these methods provide insights into clotting and fibrinolysis, they require milliliters of blood which can worsen anemia or only provide partial information. To overcome these limitations, a high-frequency photoacoustic (HFPA) imaging system was developed to detect clotting and lysis in blood. Clotting was initiated in vitro in reconstituted blood using thrombin and lysed with urokinase plasminogen activator. Frequency spectra measured using HFPA signals (10-40 MHz) between non-clotted blood and clotted blood differed markedly, allowing tracking of clot initiation and lysis in volumes of blood as low as 25 µL/test. HFPA imaging shows potential as a point-of-care examination of coagulation and fibrinolysis.
Clotting is a physiological process that prevents blood loss after injury. An imbalance in clotting factors can lead to lethal consequences such as exsanguination or inappropriate thrombosis. Clinical methods to monitor clotting and fibrinolysis typically measure the viscoelasticity of whole blood or optical density of plasma over time. Though these methods provide insights into clotting and fibrinolysis, they require milliliters of blood which can worsen anemia or only provide partial information. To overcome these limitations, a high-frequency photoacoustic (HFPA) imaging system was developed to detect clotting and lysis in blood. Clotting was initiated in vitro in reconstituted blood using thrombin and lysed with urokinase plasminogen activator. Frequency spectra measured using HFPA signals (10-40 MHz) between non-clotted blood and clotted blood differed markedly, allowing tracking of clot initiation and lysis in volumes of blood as low as 25 µL/test. HFPA imaging shows potential as a point-of-care examination of coagulation and fibrinolysis.