Related Experiment Video
Updated: Aug 1, 2025

Detection of Architectural Distortion in Prior Mammograms via Analysis of Oriented Patterns
Published on: August 30, 2013
Reliability of radiologists' first impression when interpreting a screening mammogram
Ziba Gandomkar1, Somphone Siviengphanom1, Mo'ayyad Suleiman1
1Image Optimisation and Perception Group (MIOPeG), Discipline of Clinical Imaging, Faculty of Medicine and Health, University of Sydney, Sydney, NSW, Australia.
Abstract:
Previous studies showed that radiologists can detect the gist of an abnormality in a mammogram based on a half-second image presentation through global processing of screening mammograms. This study investigated the intra- and inter-observer reliability of the radiologists' initial impressions about the abnormality (or "gist signal"). It also examined if a subset of radiologists produced more reliable and accurate gist signals. Thirty-nine radiologists provided their initial impressions on two separate occasions, viewing each mammogram for half a second each time. The intra-class correlation (ICC) values showed poor to moderate intra-reader reliability. Only 13 radiologists had an ICC of 0.6 or above, which is considered the minimum standard for reliability, and only three radiologists had an ICC exceeding 0.7. The median value for the weighted Cohen's Kappa was 0.478 (interquartile range = 0.419-0.555). The Mann-Whitney U-test showed that the "Gist Experts", defined as those who outperformed others, had significantly higher ICC values (p = 0.002) and weighted Cohen's Kappa scores (p = 0.026). However, even for these experts, the intra-radiologist agreements were not strong, as an ICC of at least 0.75 indicates good reliability and the signal from none of the readers reached this level of reliability as determined by ICC values. The inter-reader reliability of the gist signal was poor, with an ICC score of 0.31 (CI = 0.26-0.37). The Fleiss Kappa score of 0.106 (CI = 0.105-0.106), indicating only slight inter-reader agreement, confirms the findings from the ICC analysis. The intra- and inter-reader reliability analysis showed that the radiologists' initial impressions are not reliable signals. In particular, the absence of an abnormal gist does not reliably signal a normal case, so radiologists should keep searching. This highlights the importance of "discovery scanning," or coarse screening to detect potential targets before ending the visual search.
Related Concept Videos
Radiological Investigation I: X-ray and CT
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Magnetic Resonance Imaging
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
X-ray Imaging
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...