Related Experiment Video
Updated: Aug 1, 2025

Troubleshooting FoCUS Image Acquisition: Patient Positioning, Transducer Manipulation, and Image Optimization
Published on: March 3, 2023
Using computed tomography fusion imaging as learning data for sonographer training in identification of left
Yoshiki Shiina1, Tomoko Ishizu2, Satomi Nesaki1
1Department of Clinical Laboratory, University of Tsukuba Hospital, Faculty of Medicine, University of Tsukuba, Tsukuba, Japan.
Background:
We hypothesized that if computed tomography (CT) images were used as learning data, we could overcome volume underestimation by echocardiography, improving the accuracy of left ventricular (LV) volume measurements.
Methods:
We utilized a fusion imaging modality consisting of echocardiography with superimposed CT images for 37 consecutive patients to identify the endocardial boundary. We compared LV volumes obtained with and without CT learning trace-lines (TLs). Furthermore, 3D echocardiography was used to compare LV volumes obtained with and without CT learning for endocardial identification. The mean difference between the echocardiography and CT-derived LV volumes and the coefficient of variation were compared pre- and post-learning. Bland-Altman analysis was used to assess the differences in LV volume (mL) obtained from the 2D pre-learning TL and 3D post-learning TL.
Results:
The post-learning TL was located closer to the epicardium than the pre-learning TL. This trend was particularly pronounced in the lateral and the anterior wall. The post-learning TL was along the inner side of the high echoic layer in the basal-lateral wall in the four-chamber view. CT fusion imaging determined that the difference in LV volume between 2D echocardiography and CT was small (-25.6 ± 14.4 mL before learning, -6.9 ± 11.5 mL after learning) and that CT learning improved the coefficient of variation (10.9 % before learning, 7.8 % after learning). Significant improvements were observed during 3D echocardiography; the difference in LV volume between 3D echocardiography and CT was slight (-20.5 ± 15.1 mL before learning, 3.8 ± 15.7 mL after learning), and the coefficient of variation improved (11.5 % before learning, 9.3 % after learning).
Conclusions:
Differences between the LV volumes obtained using CT and echocardiography either disappeared or were reduced after CT fusion imaging. Fusion imaging is useful in training regimens for accurate LV volume quantification using echocardiography and may contribute to quality control.
Related Concept Videos
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...
Imaging Studies II: Ultrasonography
Imaging Studies for Cardiovascular System V: CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography