Related Experiment Video
Updated: Aug 1, 2025

Low-Cost, Volume-Controlled Dipstick Urinalysis for Home-Testing
Published on: May 8, 2021
Comparative Evaluation between Visual and Automated Dipstick Urinalyses in Dogs.
Erasmia D Smyroglou1, Labrini V Athanasiou2, Rania D Baka1
1Diagnostic Laboratory, Companion Animal Clinic, School of Veterinary Medicine, Faculty of Health Sciences, Aristotle University of Thessaloniki, 54627 Thessaloniki, Greece.
Visual and automated urinalysis methods show poor agreement for most canine urine parameters, except pH. Consistent use of a single method is crucial for accurate canine health assessments.
Area of Science:
- Veterinary diagnostics
- Clinical pathology
Background:
- Urine test strips offer semi-automated or visual assessment options.
- Comparing these methods is essential for reliable canine urinalysis.
Purpose of the Study:
- To compare visual and automated evaluations of canine urine dipstick variables.
- To assess the agreement between two distinct urinalysis methods.
Main Methods:
- 119 canine urine samples were analyzed.
- Automated analysis used URIT-50Vet analyzer with UC VET13 Plus strips.
- Visual evaluation used Multistix 10 SG dipsticks and a refractometer.
Main Results:
- Linear relationship found for pH (p=0.2).
- Poor agreement for specific gravity (p=0.01), ketones (κ=-0.006), and leukocytes (κ=0.100).
- Moderate agreement for protein (κ=0.431), bilirubin (κ=0.434), and glucose (κ=0.450); substantial for blood (κ=0.620).
Conclusions:
- Visual and automated dipstick urinalyses are not interchangeable, except for pH.
- Consistent method application is vital for accurate canine urine sample evaluation.
- Method discrepancies can lead to erroneous diagnostic results.