Related Experiment Video
Updated: Aug 1, 2025

Conformable Wearable Electrodes: From Fabrication to Electrophysiological Assessment
Published on: July 22, 2022
Hierarchically resistive skins as specific and multimetric on-throat wearable biosensors
Shu Gong1, Xin Zhang2,3, Xuan Anh Nguyen4
1Department of Chemical and Biological Engineering, Monash University, Melbourne, Australia.
Abstract:
Resistive skin biosensors refer to a class of imperceptible wearable devices for health monitoring and human-machine interfacing, in which conductive materials are deposited onto or incorporated into an elastomeric polymeric sheet. A wide range of resistive skins has been developed so far to detect a wide variety of biometric signals including blood pressure, skin strain, body temperature and acoustic vibrations; however, they are typically non-specific, with one resistive signal corresponding to a single type of biometric data (one-mode sensors). Here we show a hierarchically resistive skin sensor made of a laminated cracked platinum film, vertically aligned gold nanowires and a percolated gold nanowire film, all integrated into a single sensor. As a result, hierarchically resistive skin displays a staircase-shaped resistive response to tensile strain, with distinct sensing regimes associated to a specific active material. We show that we can, through one resistive signal, identify up to five physical or physiological activities associated with the human throat speech: heartbeats, breathing, touch and neck movement (that is, a multimodal sensor). We develop a frequency/amplitude-based neural network, Deep Hybrid-Spectro, that can automatically disentangle multiple biometrics from a single resistive signal. This system can classify 11 activities-with different combinations of speech, neck movement and touch-with an accuracy of 92.73 ± 0.82% while simultaneously measuring respiration and heart rates. We validated the classification accuracy of several biometrics with an overall accuracy of >82%, demonstrating the generality of our concept.
Related Concept Videos
Design Example: Resistive Touchscreen
When a user touches the screen, the two layers make contact at a specific point known as the touchpoint. This contact reduces the resistance between...
Sensory Functions of the Skin
There are two main categories of receptors on the skin: capsulated and non-capsulated. The non-capsulated ones are mainly the pain receptors. The capsulated ones can be further categorized based on the...
Physiological Barriers
The blood endothelial barrier is the most porous of these. It allows all small ionized, un-ionized, and lipophilic molecules to pass through the endothelial lining into the interstitial space...

