Comparison of cardiac index measurements in intensive care patients using continuous wave vs. pulsed wave

Prashant Parulekar1, James Powys-Lybbe2, Paul Bassett3

  • 1Intensive Care and Acute Medicine, East Kent Hospitals University NHS Foundation Trust, William Harvey Hospital, London, UK. parulekar79@gmail.com.

Insights

Continuous wave Doppler velocity time integral (CW-VTI) may offer a more accurate assessment of cardiac index (CI) compared to pulsed wave Doppler (PW-VTI) in critical care. However, neither Doppler method may accurately reflect actual CI if using a 30% percentage error cutoff.

Area of Science:

  • Critical care medicine
  • Cardiovascular physiology
  • Medical imaging and diagnostics

Background:

  • Cardiac index (CI) is crucial for shock assessment and guiding resuscitation in critical care.
  • Echocardiography offers a non-invasive method for CI assessment, showing good agreement with thermodilution methods.
  • CI is calculated using the velocity time integral (VTI) divided by body mass index.

Purpose of the Study:

  • To compare the accuracy of continuous wave Doppler (CW-VTI) and pulsed wave Doppler (PW-VTI) in assessing cardiac index against thermodilution.
  • To evaluate the potential of CW-VTI as a more accurate echocardiographic method for CI assessment.

Main Methods:

  • A prospective, observational study was conducted in a 15-bed intensive care unit.
  • Simultaneous measurements of CI were performed using Pulse Contour Cardiac Output (PiCCO) thermodilution, transthoracic echocardiographic PW-VTI, and CW-VTI.
  • Data analysis included Bland-Altman limits of agreement and percentage error (PE) calculations.

Main Results:

  • Data from 52 patients, 71% on noradrenaline, were analyzed.
  • Mean CIs: CW-VTI 2.7 L/min/m², PW-VTI 2.33 L/min/m², PiCCO 2.86 L/min/m².
  • Percentage errors (PE) with PiCCO: CW-VTI 43.5%, PW-VTI 38.6%.

Conclusions:

  • Both CW-VTI and PW-VTI methods underestimated CI compared to PiCCO.
  • CW-VTI showed closer agreement with PiCCO than PW-VTI, suggesting potential for more accurate CI assessment.
  • Neither Doppler method achieved a 30% PE, indicating potential limitations in accurately reflecting actual CI in this cohort.
Abstract

Related Concept Videos

Pulse rhythm01:30

Pulse rhythm

Pulse rhythm refers to the pattern of pulsations within specific intervals, offering valuable insights into the regularity or irregularity of the heart's beats as observed through the pattern of pulsation within specific intervals. A regular pulse exhibits a consistent heart rate with uniform waveforms and pulsation force, variations of which can be classified as normal, weak, or bounding.
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
861
Pulse01:05

Pulse

The pulse is one of the most fundamental physiological indicators of the body's cardiovascular health. It is the rhythmic expansion and contraction of the arterial walls in response to the pressure generated by the heart's pumping action.
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls...
943
Equipments Used To Measure Blood Pressure01:30

Equipments Used To Measure Blood Pressure

Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
1.1K
Cardiac Output II: Effect of Stroke Volume on Cardiac Output01:22

Cardiac Output II: Effect of Stroke Volume on Cardiac Output

Cardiac output (CO), the amount of blood the heart pumps per minute, is a parameter in cardiovascular physiology determined by stroke volume and heart rate. Stroke volume, the amount of blood pushed from one of the ventricles per heartbeat, is influenced by preload, afterload, and contractility.
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
1.1K
Cardiac Output I:Effect of Heart Rate on Cardiac Output01:19

Cardiac Output I:Effect of Heart Rate on Cardiac Output

Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart...
942
Cardiac Output and Stroke Volume01:11

Cardiac Output and Stroke Volume

Cardiac output (CO) is an integral aspect of human physiology, reflecting the heart's efficiency and responsiveness to the body's needs. It represents the volume of blood that the left or right ventricle ejects into the aorta or pulmonary trunk each minute. The CO is calculated by multiplying the heart rate (HR)—the number of heartbeats per minute—by the stroke volume (SV)—the amount of blood pumped out with each heartbeat.
In an average resting adult male, the typical cardiac...
3.1K