Related Experiment Video
Updated: Aug 1, 2025

Endoscopic Ultrasound-Guided Biliary Drainage: Endoscopic Ultrasound-Guided Hepaticogastrostomy in Malignant Biliary Obstruction
Published on: March 25, 2022
Guide Wire Selection (Straight vs. Angled) in Endoscopic Retrograde Cholangiopancreatography Using a Normal Contrast
Takumi Maki1,2,3, Atsushi Irisawa1,3, Akira Yamamiya3
1Department of Gastroenterology, Aizu Medical Center, Fukushima Medical University, 21-2 Kawahigashi Aizuwakamatsu, Fukushima 969-3482, Japan.
Introduction:
Wire-guided cannulation (WGC) during endoscopic retrograde cholangiopancreatography (ERCP) is a selective biliary cannulation technique aimed at improving the successful selective biliary cannulation rate and reducing the rate of post-ERCP pancreatitis (PEP) incidence. This study aimed to evaluate the effectiveness of angled-tip guidewires (AGW) vs. straight-tip guidewires (SGW) for biliary cannulation via WGC by a trainee.
Methods:
We conducted a prospective, single-center, open-labeled, randomized, and controlled trial. Fifty-seven patients were enrolled in this study and assigned randomly to two groups (Group A to S and Group S to A). In this study, we started selective biliary cannulation via WGC with an AGW or an SGW for 7 min. If cannulation was unsuccessful, the other guidewire was used, and cannulation was continued for another 7 min (cross-over method).
Results:
The selective biliary cannulation success rate over 14 min was significantly higher with an AGW compared with an SGW over 14 min (57.8% vs. 34.3%, p = 0.04) and for the second 7-min segment (36.4% vs. 0%, p = 0.04). No significant difference was found for adverse events such as pancreatitis between the two guidewires.
Conclusions:
Our results suggest that an AGW is recommended for WGC performed by a trainee.
Related Concept Videos
Endoscopic Procedures V: ERCP
Patient...
Cardiac Catheterization I: Pre-Procedure Overview