Proposal of Evaluation Method for Crack Propagation Behaviors of Second-Generation Acrylic Adhesives under Mode I
Yuki Ogawa1,2, Kimiyoshi Naito1,3, Keisuke Harada1,4
1Polymer Matrix Hybrid Composite Materials Group, Research Center for Structural Materials, National Institute of Materials Science, 1-2-1 Sengen, Tsukuba 305-0047, Japan.
Abstract:
Second-generation acrylic (SGA) adhesives, possessing high strength and toughness, are applicable in automotive body structures. Few studies have considered the fracture toughness of the SGA adhesives. This study entailed a comparative analysis of the critical separation energy for all three SGA adhesives and an examination of the mechanical properties of the bond. Loading-unloading test was performed to evaluate crack propagation behaviors. In the loading-unloading test of the SGA adhesive with high ductility, plastic deformation was observed in the steel adherends; the arrest load dominated the propagation and non-propagation of crack for adhesive. The critical separation energy of this adhesive was assessed by the arrest load. In contrast, for the SGA adhesives with high tensile strength and modulus, the load suddenly decreased during loading, and the steel adherend was not plastically deformed. The critical separation energies of these adhesives were assessed using the inelastic load. The critical separation energies for all the adhesives were higher for thicker adhesive. Particularly, the critical separation energies of the highly ductile adhesives were more affected by the adhesive thickness than highly strength adhesives. The critical separation energy from the analysis using the cohesive zone model agreed with the experimental results.
Related Concept Videos
Microcracking in Concrete
Behavior of Concrete Under Compressive Load
As the concrete specimen fractures under...
Plastic Behavior
Normal Strain under Axial Loading
Residual Stresses in Bending
Dynamic Modulus of Elasticity of Concrete
The sonic test is a common method to determine the dynamic modulus. In this test, a concrete beam, sized either 6 x 6 x 30 inches or 4 x 4 x 20 inches, is clamped at its center. Vibrations are initiated at one end of the beam by an electromagnetic exciter unit powered by...