Related Experiment Video
Updated: Aug 1, 2025

05:30
Large Scale Energy Efficient Sensor Network Routing Using a Quantum Processor Unit
Published on: September 8, 2023
611
Relay Selection for Over-the-Air Computation Achieving Both Long Lifetime and High Reliability
1Department of Computer and Network Engineering, The University of Electro-Communications, Tokyo 182-8585, Japan.
Sensors (Basel, Switzerland)
|April 28, 2023
Summary
This study introduces a relay selection protocol for over-the-air computation (AirComp) in wireless sensor networks. The proposed method enhances network lifetime and reduces computation errors, especially for nodes with low channel gain.
Area of Science:
- Wireless Sensor Networks
- Communication Systems
- Signal Processing
Background:
- Conventional wireless sensor networks face scalability issues with increasing node counts, leading to longer data collection/processing times and degraded spectrum efficiency.
- Over-the-air computation (AirComp) offers an efficient alternative for statistical data aggregation but struggles with low channel gain nodes, causing high transmission power and computation errors.
Purpose of the Study:
- To investigate relay communication strategies for AirComp to address challenges posed by low channel gain nodes.
- To develop and evaluate a relay selection protocol that jointly optimizes computation error and power consumption, while considering network lifetime.
Main Methods:
- Proposed a relay selection protocol for AirComp, initially selecting ordinary nodes with good channel conditions based on computation error and power consumption.
- Enhanced the protocol to explicitly incorporate network lifetime considerations into the relay selection process.
Main Results:
- The proposed relay selection protocol effectively mitigates issues associated with low channel gain nodes in AirComp systems.
- Simulation results demonstrate that the enhanced protocol significantly prolongs the overall network lifetime.
- The method also shows a marked reduction in computation errors compared to conventional approaches.
Conclusions:
- Relay communication is a viable strategy to enhance the performance of AirComp in wireless sensor networks.
- The developed relay selection protocol offers a practical solution for improving network lifetime and accuracy in AirComp systems.
- Explicitly considering network lifetime in relay selection is crucial for sustainable and efficient wireless sensor network operation.
More Related Videos
Related Concept Videos
Pilot and Numeric Relaying
111
Pilot relaying is a type of differential protection used in power systems. It compares electrical quantities at the terminals of equipment via a communication channel instead of direct relay interconnection. This method is essential for transmission lines where the terminals are far apart, typically up to 80 km for lines with 69 to 115 kV ratings. Four types of communication channels are used for pilot relaying:
111
Differential Relays
205
Differential relays are used to protect generators, buses, and transformers by comparing electrical quantities at different points. When a fault occurs, the difference in current between the two points triggers the relay to operate, opening the circuit breaker. Under normal conditions, the current entering (i1) and leaving (i2) a generator are equal. When a fault occurs, however, these currents become unequal, and the difference current flows in the relay operating coil, causing the relay to...
205
Maximum Power Transfer
306
Numerous practical applications within engineering disciplines, such as telecommunications, necessitate optimizing power delivery to a connected load. This pursuit, however, entails inherent internal losses, which can either equal or exceed the power supplied to the load. The Thevenin equivalent circuit is helpful in finding the maximum power a linear circuit can deliver to a load. It is assumed in this context that the load resistance can be adjusted.
By substituting the entire circuit with...
By substituting the entire circuit with...
306
Overcurrent Relays
129
Overcurrent relays, crucial for circuit protection, are connected to the secondary current of a current transformer. There are two primary types of overcurrent relays: instantaneous and time-delay.
Instantaneous overcurrent relays activate immediately when the input current exceeds a predetermined value, known as the pickup current, instantly energizing the circuit breaker trip coil. This rapid response is vital for addressing severe faults quickly.
Time-delay overcurrent relays, on the other...
Instantaneous overcurrent relays activate immediately when the input current exceeds a predetermined value, known as the pickup current, instantly energizing the circuit breaker trip coil. This rapid response is vital for addressing severe faults quickly.
Time-delay overcurrent relays, on the other...
129
Distribution Reliability and Automation
138
Distribution reliability in electrical power systems is critical for ensuring an uninterrupted power supply to consumers at minimal cost. According to IEEE Standard Terms, reliability is the probability that a device will function without failure over a specified time period or amount of usage. For electric power distribution, this translates to maintaining continuous power supply and addressing customer concerns over power outages. Several indices, as defined by IEEE Standard 1366-2012, are...
138
Directional Relays
154
Directional relays, essential for managing unidirectional fault currents, enhance the safety and efficiency of power systems. On power lines equipped with directional relays, faults downstream (to the right) of the current transformer typically cause the fault current to lag the bus voltage by approximately 90 degrees, known as the forward direction. In contrast, upstream (left-side) faults may result in the fault current leading the bus voltage by nearly 90 degrees, termed the reverse...
154