T-type cell mediated photoacoustic spectroscopy for simultaneous detection of multi-component gases based on triple
Le Zhang1, Lixian Liu1, Xueshi Zhang1
1School of Optoelectronic Engineering, Xidian University, Xi'an 710071, China.
Abstract:
Enhancing multi-gas detectability using photoacoustic spectroscopy capable of simultaneous detection, highly selectivity and less cross-interference is essential for dissolved gas sensing application. A T-type photoacoustic cell was designed and verified to be an appropriate sensor, due to the resonant frequencies of which are determined jointly by absorption and resonant cylinders. The three designated resonance modes were investigated from both simulation and experiments to present the comparable amplitude responses by introducing excitation beam position optimization. The capability of multi-gas detection was demonstrated by measuring CO, CH4 and C2H2 simultaneously using QCL, ICL and DFB lasers as excitation sources respectively. The influence of potential cross-sensitivity towards humidity have been examined in terms of multi-gas detection. The experimentally determined minimum detection limits of CO, CH4 and C2H2 were 89ppb, 80ppb and 664ppb respectively, corresponding to the normalized noise equivalent absorption coefficients of 5.75 × 10-7 cm-1 W Hz-1/2, 1.97 × 10-8 cm-1 W Hz-1/2 and 4.23 × 10-8 cm-1 W Hz-1/2.
Related Concept Videos
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Tandem Mass Spectrometry
Secondary fragmentations occur in the interaction cell and can be induced by various factors. Fragmentation induced by collision with inert gases, such as N2, Ar, He, etc., is called collision-induced...
Double Resonance Techniques: Overview
Spin decoupling is usually achieved by...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...