Related Experiment Video
Updated: Aug 1, 2025

Standards for Quantitative Metalloproteomic Analysis Using Size Exclusion ICP-MS
Published on: April 13, 2016
Paraproteins and electrolyte assays: exclusion effect and effect of paraprotein elimination
Tapio Lahtiharju1, Eerika Lehtisyrjä2, Pipsa Kulovesi1
1Clinical Chemistry, HUSLAB Laboratory Services, HUS Diagnostics Centre, Helsinki University Hospital and University of Helsinki, Helsinki, Finland.
Abstract:
Paraproteins are a potential source of error for electrolyte analyses. The exclusion effect itself causes a discrepancy between direct and indirect ion selective electrode assays (dISE and iISE, respectively). We tested the applicability of different pretreatment methods and the difference of dISE and iISE with paraprotein-rich samples. We analysed chloride (Cl-), potassium (K+), and sodium (Na+) on 46 samples with paraproteins up to 73 g/L. We compared pretreatment methods of preheating, precipitation, and filtration to the native sample. All induced a statistically significant difference (p-value <0.05). Clinically significant difference was induced by precipitation for all analytes, and filtration for Cl- and Na+, but for none by preheating. The difference in electrolyte measurements with either dISE or iISE on native samples was explained by total protein concentration (TP). There was a statistically significant difference in all electrolyte measurements. On average, there was a clinically significant difference in Na + but not in Cl- and K + measurements. Paraprotein concentration (PP) or heavy chain class did not induce a statistically significant effect. The regression analysis and comparison to the theoretical exclusion effect supported the conclusion that TP is the only explanatory factor in the difference between dISE and iISE. We conclude that preheating is a suitable pretreatment method for all the studied analytes. Precipitation is not valid for any of them, and filtration can be considered only for K+. Because the difference between dISE and iISE was explained by the exclusion effect caused by TP, dISE is the more suitable method to analyse paraprotein-rich samples.
More Related Videos
09:32Procedure and Key Optimization Strategies for an Automated Capillary Electrophoretic-based Immunoassay Method
Published on: September 10, 2017
07:52Detection of Antibodies That Neutralize the Cellular Uptake of Enzyme Replacement Therapies with a Cell-based Assay
Published on: September 10, 2018
Related Concept Videos
Drug Elimination by Renal Route: Tubular Reabsorption
Drug Elimination by Renal Route: Tubular Secretion
Renal Drug Excretion: Effect of Urine pH, Flow Rate, and Drug pKa
The pKa of a...
Enhanced Elimination of Poison
Antidotes serve a crucial role in counteracting the effects of poison by inhibiting enzymes responsible for producing harmful drug metabolites. In some cases, these toxic metabolites can be neutralized by endogenous cosubstrates, which are maintained at specific concentrations to prevent interaction with cellular macromolecules and subsequent cell death.
Renal excretion is the...
Renal Drug Excretion: Tubular Secretion
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...