Related Experiment Video
Updated: Aug 1, 2025

An Anaerobic Biosensor Assay for the Detection of Mercury and Cadmium
Published on: December 17, 2018
Activated carbon based paste electrodes for the simultaneous and effective detection of divalent cadmium and lead
S P Aravind1, T P Anandhu1, Karthik Jayakumar1
1Department of Chemical Engineering, National Institute of Technology Calicut, Calicut, India.
Abstract:
Heavy metals (HM) have gained significant attention in terms of regular monitoring and detection owing to their toxicity, non-biodegradability, and persistence. Current techniques for detecting HM are expensive, cumbersome, and require sophisticated instruments and skilled labour. Hence, developing cheap, rapid, energy-efficient, and accurate sensors is imperative and electrochemical techniques have emerged as promising tools. The current study involves the fabrication of an electrochemical sensor for the concurrent detection of lead (Pb2+) and cadmium (Cd2+) ions using modified carbon paste electrodes (mCPE). Activated carbon (AC) with a BET surface area of 1118 m2 g-1 was obtained by chemical activation and thermal treatment of the waste rubberwood sawdust. AC-Graphite, AC-Reduced Graphene Oxide (RGO), and AC-RGO-Chitosan were the types of mCPEs that were utilised. The electrochemical behaviours and effects of pH, concentration, and scan rate were studied using Cyclic voltammetry (CV). Studies on detection were conducted using CV and linear sweep voltammetry. Although all the 3 mCPEs detected Cd2+ and Pb2+ in the simulated wastewater, the CPE with RGO and AC could detect Cd2+ as low as 10.91 µg L-1 and Pb2+ as low as 14.01 µg L-1. The work explored the possibility of using AC as a potential sustainable substitute for graphite in CPE.
More Related Videos
10:31Detection and Recovery of Palladium, Gold and Cobalt Metals from the Urban Mine Using Novel Sensors/Adsorbents Designated with Nanoscale Wagon-wheel-shaped Pores
Published on: December 6, 2015
08:19Hollow Microneedle-based Sensor for Multiplexed Transdermal Electrochemical Sensing
Published on: June 1, 2012
Related Concept Videos
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
Potentiometry: Membrane Electrodes
Electrodeposition
Electrodeposition can...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Controlled-Potential Coulometry: Electrolytic Methods
The chosen potential...