Related Experiment Video
Updated: Aug 1, 2025

Assessing Changes in Volatile General Anesthetic Sensitivity of Mice after Local or Systemic Pharmacological Intervention
Published on: October 16, 2013
Effects of Anesthesia Changes During Maintenance ECT: A Longitudinal Comparison of Seizure Quality Under Anesthesia
Isabel Methfessel1, David Zilles-Wegner1, Nils Kunze-Szikszay2
1Department of Psychiatry and Psychotherapy, University Medical Center Göttingen, Göttingen, Germany.
Introduction:
The effectiveness of ECT relies on the induction of a generalized cerebral seizure. Among others, seizure quality (SQ) is potentially influenced by the anesthetic drug used. Commonly used anesthetics comprise barbiturates, etomidate, propofol, and esketamine, with different characteristics and impacts on seizure parameters. So far, no studies have compared the influence of methohexital vs. a combination of propofol/esketamine on established SQ parameters.
Methods:
This retrospective longitudinal study compared eight established SQ parameters (PSI, ASEI, MSC, midictal amplitude, motor and electroencephalography (EEG) seizure duration, concordance, PHR) before and after the change from propofol/esketamine to methohexital in 34 patients under maintenance ECT. Each patient contributed four measurements, two before and two after the anesthesia change. Anesthesia dose, stimulus dose, electrode placement, and concomitant medication remained unchanged throughout the analyzed treatments.
Results:
Under methohexital (M=88.97 mg), ASEI (p=0.039 to 0.013) and midictal amplitude (p=0.022 to<0.001) were significantly lower, whereas seizure duration (motor and EEG) was significantly longer when compared to propofol/esketamine (M=64.26 mg/51.18 mg; p=0.012 to<0.001). PSI, MSC, seizure concordance, and PHR were not affected by the anesthetic used.
Discussion:
Although to what extent these parameters correlate with the therapeutic effectiveness remains ambiguous, a decision for or against a particular anesthetic could be considered if a specific SQ parameter needs optimization. However, no general superiority for one specific substance or combination was found in this study. In the next step, anesthetic effects on treatment response and tolerability should be focused on.
More Related Videos
14:52Recording Brain Electromagnetic Activity During the Administration of the Gaseous Anesthetic Agents Xenon and Nitrous Oxide in Healthy Volunteers
Published on: January 13, 2018
10:23Equipment Setup and Artifact Removal for Simultaneous Electroencephalogram and Functional Magnetic Resonance Imaging for Clinical Review in Epilepsy
Published on: June 23, 2023
Related Concept Videos
Parenteral Anesthetics: Overview
Stages of General Anesthesia
Inhalational Anesthetics: Overview
General Anesthesia: Overview
General anesthesia induces unconsciousness in the whole body, while the others target specific areas or sensations. It is administered to minimize adverse effects, maintain...
Local Anesthetics: Clinical Application as Epidural Anesthesia
Since epidural anesthetics can be infused through an epidural catheter, all types of drugs, including short-acting ones, can be administered. Chloroprocaine and lidocaine are examples of short and long-duration anesthetics, respectively. Bupivacaine...
Local Anesthetics: Pharmacokinetics