Investigation into Deep Breathing through Measurement of Ventilatory Parameters and Observation of Breathing Patterns
Published on: September 16, 2019
A Systematic Review of Methods Used to Determine the Work of Breathing during Exercise
Troy J Cross1, Jennifer M J Isautier1, Eli F Kelley2
1Faculty of Medicine and Health, University of Sydney, NSW, AUSTRALIA.
Introduction:
Measurement of the work of breathing (Wb) during exercise provides useful insights into the energetics and mechanics of the respiratory muscles across a wide range of minute ventilations. The methods and analytical procedures used to calculate the Wb during exercise have yet to be critically appraised in the literature.
Purpose:
The aim of this systematic review was to evaluate the quality of methods used to measure the Wb during exercise in the available literature.
Methods:
We conducted an extensive search of three databases for studies that measured the Wb during exercise in adult humans. Data were extracted on participant characteristics, flow/volume and pressure devices, esophageal pressure (P oes ) catheters, and methods of Wb analysis.
Results:
A total of 120 articles were included. Flow/volume sensors used were primarily pneumotachographs ( n = 85, 70.8%), whereas the most common pressure transducer was of the variable reluctance type ( n = 63, 52.5%). Esophageal pressure was frequently obtained via balloon-tipped catheters ( n = 114, 95.0%). Few studies mentioned calibration, frequency responses, and dynamic compensation of their measurement devices. The most popular method of measuring the Wb was pressure-volume integration ( n = 51, 42.5%), followed by the modified Campbell ( n = 28, 23.3%) and Dean & Visscher diagrams ( n = 26, 21.7%). Over one-third of studies did not report the methods used to process their pressure-volume data, and the majority (60.8%) of studies used the incorrect Wb units and/or failed to discuss the limitations of their Wb measurements.
Conclusions:
The findings of this systematic review highlight the need for the development of a standardized approach for measuring Wb, which is informative, practical, and accessible for future researchers.
More Related Videos
08:44Author Spotlight: Integrating Alveolar-Capillary Reserve Measurements in Exercise Adaptation and Therapeutic Strategies
Published on: February 2, 2024
07:09Assessment of Pulmonary Capillary Blood Volume, Membrane Diffusing Capacity, and Intrapulmonary Arteriovenous Anastomoses During Exercise
Published on: February 20, 2017
Related Concept Videos
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Physical Assessment of the Respiratory Tract II: Inspection
Chest Configuration
The chest configuration...
Assessment of Respiration
Subjective Assessment: Nurses interview the patient to gather information directly during the subjective assessment. It includes questions about the individual's medical history, medications, and symptoms, focusing on past respiratory conditions like...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Assessment of Airway, Skin Color, and Use of Accessory Muscles
Introduction
The initial evaluation of a patient's respiratory system...
Chronic Obstructive Pulmonary Disease-IV: Assessement and Diagnostic Studies
Medical History