Value of Autostrain LV in the study of left ventricular systolic function and synchronization in patients with

Wanqing Li1, Lili Ge1, Yuhong Li1

  • 1Department of Ultrasound, The First Affiliated Hospital of Jinzhou Medical University, Jinzhou, Liaoning, China.

Insights

Systemic lupus erythematosus (SLE) can cause cardiac issues. Autostrain LV and 3DQA can detect early myocardial strain and synchrony changes in SLE patients, aiding prognosis.

Area of Science:

  • Cardiology
  • Rheumatology
  • Medical Imaging

Background:

  • Cardiac abnormalities in Systemic Lupus Erythematosus (SLE) are understudied.
  • Cardiovascular events significantly impact SLE patient prognosis.
  • Early assessment of myocardial systolic function and synchrony is crucial for SLE management.

Purpose of the Study:

  • To evaluate early changes in left ventricular myocardial strain and synchrony in SLE patients.
  • To compare the effectiveness of Autostrain LV and 3D quantitative analysis (3DQA) in assessing cardiac function in SLE.
  • To establish the reproducibility of these imaging techniques.

Main Methods:

  • Ninety SLE patients were stratified into stable, mildly active, and moderately active groups based on SLE Disease Activity Index (SLE-DAI-2000) scores.
  • Thirty healthy individuals served as controls.
  • Autostrain LV and 3DQA were employed to measure left ventricular systolic function, strain parameters, and synchrony.

Main Results:

  • Increased SLE disease activity correlated with decreased longitudinal strain and increased strain peak time standard deviation (Tls-SD).
  • SLE patients exhibited prolonged synchrony parameters (Tmsv-17-SD, Tmsv-17-Dif) compared to controls.
  • Autostrain LV and 3DQA showed good agreement in measuring synchrony, with 3DQA demonstrating superior repeatability.

Conclusions:

  • Autostrain LV effectively detects early left ventricular myocardial strain changes in SLE.
  • 3DQA quantitatively assesses left ventricular systolic synchrony in SLE patients.
  • Both methods are reproducible, with 3DQA offering higher sensitivity for detecting synchronous motion changes.
Abstract