Related Experiment Video
Updated: Jul 31, 2025

Estimating Bilateral Atrial Function by Cardiovascular Magnetic Resonance Feature Tracking in Patients with Paroxysmal Atrial Fibrillation
Published on: July 20, 2022
P-wave terminal force in lead V1 and atrial fibrillation burden in cryptogenic stroke with implantable loop recorders
Hajime Ikenouchi1, Junpei Koge2, Tomotaka Tanaka3
1Department of Cerebrovascular Medicine, National Cerebral and Cardiovascular Center, 6-1 Kishibe-Shimmachi, Suita, Osaka, 564-8565, Japan.
Abstract:
Implantable loop recorders (ILRs) are useful for the detection of atrial fibrillation (AF) in patients with cryptogenic stroke (CS). P-wave terminal force in lead V1 (PTFV1) is associated with AF detection; however, data on the association between PTFV1 and AF detection using ILRs in patients with CS are limited. Consecutive patients with CS with implanted ILRs from September 2016 to September 2020 at eight hospitals in Japan were studied. PTFV1 was calculated by 12-lead ECG before ILRs implantation. An abnormal PTFV1 was defined as ≥ 4.0 mV × ms. The AF burden was calculated as a proportion based on the duration of AF to the total monitoring period. The outcomes included AF detection and large AF burden, which was defined as ≥ 0.5% of the overall AF burden. Of 321 patients (median age, 71 years; male, 62%), AF was detected in 106 patients (33%) during the median follow-up period of 636 days (interquartile range [IQR], 436-860 days). The median time from ILRs implantation to AF detection was 73 days (IQR, 14-299 days). An abnormal PTFV1 was independently associated with AF detection (adjusted hazard ratio, 1.71; 95% confidence interval [CI], 1.00-2.90). An abnormal PTFV1 was also independently associated with a large AF burden (adjusted odds ratio, 4.70; 95% CI, 2.50-8.80). In patients with CS with implanted ILRs, an abnormal PTFV1 is associated with both AF detection and a large AF burden.Clinical Trial Registration Information: UMIN Clinical Trials Registry 000044366.
More Related Videos
08:05Optimization of Transesophageal Atrial Pacing to Assess Atrial Fibrillation Susceptibility in Mice
Published on: June 29, 2022
12:45Benefits of Cardiac Resynchronization Therapy in an Asynchronous Heart Failure Model Induced by Left Bundle Branch Ablation and Rapid Pacing
Published on: December 11, 2017
Related Concept Videos
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin...
Dysrhythmias IV: Characteristics of Bradyarrhythmias
Disturbances in Heart Rhythm
Arrhythmias are categorized by their speed, rhythm, and origin. A slow heart...
Cardiac Action Potential
The cardiac action potential process involves a series of phases characterized by the movement of ions across the cardiac cell membranes, leading to the depolarization and repolarization of the cardiac myocytes.
Ionic Basis of Cardiac Action Potentials
Electrophysiology of Normal Cardiac Rhythm