Chemical separation and measurement of platinum activation products
Melinda S Wren1, Iain May1, Elena Guardincerri1
1Los Alamos National Laboratory, Los Alamos, NM 87544, USA.
Abstract:
A method has been developed to purify and measure platinum radioisotopes in the presence of fission products and environmental constituents. The method uses a combination of cation exchange and anion exchange chromatography and selective precipitation steps to remove other radioisotopes from the sample. The addition of stable platinum carrier allows for a gravimetric determination of the chemical yield of the procedure. Overall, the method is fast, simple, and potentially applicable for rapid turnaround of unknown samples. Using this method, multiple platinum radioisotopes were measured in two different irradiation experiments. The measured ratios of the platinum radioisotopes clearly reflect the neutron spectrum of the irradiation, suggesting that platinum radioisotopes could be valuable signatures in nuclear forensic analyses.
More Related Videos
14:22Activating Molecules, Ions, and Solid Particles with Acoustic Cavitation
Published on: April 11, 2014
10:31Detection and Recovery of Palladium, Gold and Cobalt Metals from the Urban Mine Using Novel Sensors/Adsorbents Designated with Nanoscale Wagon-wheel-shaped Pores
Published on: December 6, 2015
Related Concept Videos
Washing, Drying, and Ignition of Precipitates
Gas Chromatography: Types of Detectors-II
Atomic Emission Spectroscopy: Lab
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...