Related Experiment Video
Updated: Jul 31, 2025

Primary Outcome Assessment in a Pig Model of Acute Myocardial Infarction
Published on: October 14, 2016
Pacing-Related Differences After SAPIEN-3 TAVI: Clinical and Echocardiographic Correlates
Yasser M Sammour1, Hassan Lak2, Rama Dilip Gajulapalli3
1Aortic Valve Center, Robert and Suzanne Tomsich Department of Cardiovascular Medicine, Sydell and Arnold Miller Family Heart Vascular & Thoracic Institute, Cleveland Clinic, Cleveland, Ohio.
Abstract:
Data regarding the impact of pacing on outcomes after transcatheter aortic valve implantation (TAVI) is evolving especially with regards to pre-existing permanent pacemaker (PPM). We examined the impact of new and previous PPM on the clinical and hemodynamic outcomes after SAPIEN-3 TAVI. We included all consecutive patients who underwent transfemoral TAVI using SAPIEN-3 valve from 2015 to 2018 at our institution. Among 1,028 patients, 10.2% required a new PPM within 30 days, whereas 14% had a pre-existing PPM. The presence of either previous or new PPM had no impact on the 3-year mortality (log-rank p = 0.6) or 1-year major adverse cardiac and cerebrovascular events (log-rank p = 0.65). New PPM was associated with lower left ventricular (LV) ejection fraction (LVEF) at both 30 days (54.4 ± 11.3% vs 58.4 ± 10.1%, p = 0.001) and 1 year (54.2 ± 12% vs 59.1 ± 9.9%, p = 0.009) than no PPM. Similarly, previous PPM was associated with worse LVEF at 30 days (53.6 ± 12.3%, p <0.001) and 1 year (55.5 ± 12.1%, p = 0.006) than no PPM. Interestingly, new PPM was associated with lower 1-year mean gradient (11.4 ± 3.8 vs 12.6 ± 5.6 mm Hg, p = 0.04) and peak gradient (21.3 ± 6.5 vs 24.1 ± 10.4 mm Hg, p = 0.01), despite no baseline differences. Previous PPM was also associated with lower 1-year mean gradient (10.3 ± 4.4 mm Hg, p = 0.001) and peak gradient (19.4 ± 8 mm Hg, p <0.001) and higher Doppler velocity index (0.51 ± 0.12 vs 0.47 ± 0.13, p = 0.039). Moreover, 1-year LV end-systolic volume index was higher with new (23.2 ± 16.1 vs 20 ± 10.8 ml/m2, p = 0.038) and previous PPM (24.5 ± 19.7, p = 0.038) than no PPM. Previous PPM was associated with higher moderate-to-severe tricuspid regurgitation (35.3% vs 17.7%, p <0.001). There were no differences regarding the rest of the studied echocardiographic outcomes at 1 year. In conclusion, new and previous PPM did not affect 3-year mortality or 1-year major adverse cardiac and cerebrovascular events; however, they were associated with worse LVEF, higher 1-year LV end-systolic volume index, and lower mean and peak gradients on follow-up than no PPM.
More Related Videos
04:48Noninvasive Determination of Vortex Formation Time Using Transesophageal Echocardiography During Cardiac Surgery
Published on: November 28, 2018
09:05Assessment of Cardiac Morphological and Functional Changes in Mouse Model of Transverse Aortic Constriction by Echocardiographic Imaging
Published on: June 21, 2016
Related Concept Videos
Acute Coronary Syndrome III: Diagnostic Studies
Aortic Regurgitation II: Clinical Features and Diagnostic Tests
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...
Aortic Regurgitation I: Introduction
Coronary Artery Disease III: Clinical Manifestations