Related Experiment Video
Updated: Jul 31, 2025

Transdermal Measurement of Glomerular Filtration Rate in Mice
Published on: October 21, 2018
Predictive performance of glomerular filtration rate equations based on cystatin C, creatinine and their combination
Marta Albanell-Fernández1, Carla Bastida2, Ángel Marcos Fendian1
1Pharmacy Service, Division of Medicines, Hospital Clinic de Barcelona, Barcelona, Catalunya, Spain.
Objective:
24-hour urine creatinine clearance (ClCr 24 hours) remains the gold standard for estimating glomerular filtration rate (GFR) in critically ill patients; however, simpler methods are commonly used in clinical practice. Serum creatinine (SCr) is the most frequently used biomarker to estimate GFR; and cystatin C, another biomarker, has been shown to reflect GFR changes earlier than SCr. We assess the performance of equations based on SCr, cystatin C and their combination (SCr-Cyst C) for estimating GFR in critically ill patients.
Methods:
Observational unicentric study in a tertiary care hospital. Patients with cystatin C, SCr and ClCr 24 hours measurements in ±2 days admitted to an intensive care unit were included. ClCr 24 hours was considered the reference method. GFR was estimated using SCr-based equations: Chronic Kidney Disease Epidemiology Collaboration based on creatinine (CKD-EPI-Cr) and Cockcroft-Gault (CG); cystatin C-based equations: CKD-EPI-CystC and CAPA; and Cr-CystC-based equations: CKD-EPI-Cr-CystC. Performance of each equation was assessed by calculating bias and precision, and Bland-Altman plots were built. Further analysis was performed with stratified data into CrCl 24 hours <60, 60-130 and ≥130 mL/min/1.73 m2.
Results:
We included 275 measurements, corresponding to 186 patients. In the overall population, the CKD-EPI-Cr equation showed the lowest bias (2.6) and best precision (33.1). In patients with CrCl 24 hours <60 mL/min/1.73 m2, cystatin-C-based equations showed the lowest bias (<3.0) and CKD-EPI-Cr-CystC was the most accurate (13.6). In the subgroup of 60≤ CrCl 24 hours <130mL/min/1.73 m2, CKD-EPI-Cr-CystC was the most precise (20.9). However, in patients with CrCl 24 hours ≥130mL/min/1.73 m2, cystatin C-based equations underestimated GFR, while CG overestimated it (22.7).
Conclusions:
Our study showed no evidence of superiority of any equation over the others for all evaluated parameters: bias, precision and Lin's concordance correlation coefficient. Cystatin C-based equations were less biased in individuals with impaired renal function (GFR <60 mL/min/1.73 m2). CKD-EPI-Cr-CystC performed properly in patients with GFR from 60-130 mL/min/1.73 m2 and none of them were accurate enough in patients ≥130 mL/min/1.73 m2.
Related Concept Videos
Factors Affecting Renal Clearance: Renal Impairment
One condition associated with renal failure is uremia. Uremia is characterized by impaired glomerular filtration and fluid accumulation in the body. This condition hinders the renal clearance of drugs, resulting in drug accumulation and potential...
Renal Clearance
Renal clearance refers to the volume of plasma cleared of a specific substance, such as creatinine, per unit of time. To measure clearance, urine samples are collected over a 24-hour period during each bladder voiding, followed by a single blood sample at the...
Chronic Kidney Disease III: Interprofessional Care
Serum Studies: Renal Function Tests
Acute Kidney Injury I: Introduction
Acute Kidney Injury IV: Diagnostic Studies and Prevention

