Related Experiment Video
Updated: Feb 9, 2026

Author Spotlight: Developing a Point-of-Care Hemoglobin Estimation Method for Anemia Management
Published on: January 19, 2024
Fluosol-DA as a red-cell substitute in acute anemia
We assessed the safety and efficacy of Fluosol-DA as a red-cell substitute in acute anemia. Twenty-three surgical patients with blood loss and religious objections to receiving blood transfusions were evaluated. Fifteen moderately anemic patients with a mean hemoglobin level (+/- SE) of 7.2 +/- 0.5 g per deciliter had no evidence of a physiologic need for increased arterial oxygen content and did not receive Fluosol-DA. Eight severely anemic patients with a mean hemoglobin level of 3.0 +/- 0.4 g per deciliter met the criteria of need and received the drug until the physiologic need disappeared or a maximal dose of 40 ml per kilogram of body weight was reached. We observed no adverse reactions to Fluosol-DA. The average peak increment in arterial oxygen content with the drug was only 0.7 +/- 0.1 ml per deciliter. There were no appreciable beneficial effects of Fluosol-DA, perhaps because of the small increase in arterial oxygen content, the brief half-life of the drug (24.3 +/- 4.3 hours), and the limited total dose. Six of the eight patients receiving Fluosol-DA died. One of the survivors received red-cell transfusions against his wishes, under a court order, after his total Fluosol-DA dose. Fourteen of the 15 moderately anemic patients survived. The data in this select group of patients refusing blood products suggest that, after blood loss, Fluosol-DA is unnecessary in moderate anemia and ineffective in severe anemia.
We assessed the safety and efficacy of Fluosol-DA as a red-cell substitute in acute anemia. Twenty-three surgical patients with blood loss and religious objections to receiving blood transfusions were evaluated. Fifteen moderately anemic patients with a mean hemoglobin level (+/- SE) of 7.2 +/- 0.5 g per deciliter had no evidence of a physiologic need for increased arterial oxygen content and did not receive Fluosol-DA. Eight severely anemic patients with a mean hemoglobin level of 3.0 +/- 0.4 g per deciliter met the criteria of need and received the drug until the physiologic need disappeared or a maximal dose of 40 ml per kilogram of body weight was reached. We observed no adverse reactions to Fluosol-DA. The average peak increment in arterial oxygen content with the drug was only 0.7 +/- 0.1 ml per deciliter. There were no appreciable beneficial effects of Fluosol-DA, perhaps because of the small increase in arterial oxygen content, the brief half-life of the drug (24.3 +/- 4.3 hours), and the limited total dose. Six of the eight patients receiving Fluosol-DA died. One of the survivors received red-cell transfusions against his wishes, under a court order, after his total Fluosol-DA dose. Fourteen of the 15 moderately anemic patients survived. The data in this select group of patients refusing blood products suggest that, after blood loss, Fluosol-DA is unnecessary in moderate anemia and ineffective in severe anemia.
Related Concept Videos
Trigonometric Substitution
Rationalizing Substitutions
Evaluating Limits by Direct Substitution
Red Algae
Diazonium Group Substitution: –OH and –H
Stability of Substituted Cyclohexanes
The two chair conformations of cyclohexanes undergo rapid interconversion at room temperature. Both forms have identical energies and stabilities, each comprising equal amounts of the equilibrium mixture. Replacing a hydrogen atom with a functional group makes the two conformations energetically non-equivalent.
For example, in...

