Related Experiment Video
Updated: Jul 6, 2026

High-Throughput, Multi-Image Cryohistology of Mineralized Tissues
Published on: September 14, 2016
Flow chamber staining modality for real-time inspection of dynamic phenotypes in multiple histological stains
Zhongmin Li1, Goetz Muench1, Silvia Goebel1
1Advancecor GmbH, Martinsried, Germany.
Abstract:
Traditional histological stains, such as hematoxylin-eosin (HE), special stains, and immunofluorescence (IF), have defined myriads of cellular phenotypes and tissue structures in a separate stained section. However, the precise connection of information conveyed by the various stains in the same section, which may be important for diagnosis, is absent. Here, we present a new staining modality-Flow chamber stain, which complies with the current staining workflow but possesses newly additional features non-seen in conventional stains, allowing for (1) quickly switching staining modes between destain and restain for multiplex staining in one single section from routinely histological preparation, (2) real-time inspecting and digitally capturing each specific stained phenotype, and (3) efficiently synthesizing graphs containing the tissue multiple-stained components at site-specific regions. Comparisons of its stains with those by the conventional staining fashions using the microscopic images of mouse tissues (lung, heart, liver, kidney, esophagus, and brain), involving stains of HE, Periodic acid-Schiff, Sirius red, and IF for Human IgG, and mouse CD45, hemoglobin, and CD31, showed no major discordance. Repetitive experiments testing on targeted areas of stained sections confirmed the method is reliable with accuracy and high reproducibility. Using the technique, the targets of IF were easily localized and seen structurally in HE- or special-stained sections, and the unknown or suspected components or structures in HE-stained sections were further determined in histological special stains or IF. By the technique, staining processing was videoed and made a backup for off-site pathologists, which facilitates tele-consultation or -education in current digital pathology. Mistakes, which might occur during the staining process, can be immediately found and amended accordingly. With the technique, a single section can provide much more information than the traditional stained counterpart. The staining mode bears great potential to become a common supplementary tool for traditional histopathology.
Related Concept Videos
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Fixation and Sectioning
The simplest type of preparation is the wet mount, in which the specimen is placed in a drop of liquid on the slide. A liquid specimen can be directly deposited on the slide using a dropper. Solid specimens, such as skin scraping, can be placed on the slide before adding a drop of liquid to prepare the wet mount. Sometimes the liquid is simply water, but stains are often added...
Two-Dimensional Microscopy in Microbiology
Simple Staining Technique

