EE-Explorer: A Multimodal Artificial Intelligence System for Eye Emergency Triage and Primary Diagnosis
Juan Chen1, Xiaohang Wu1, Mingyuan Li1
1From the State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangdong Provincial Clinical Research Center for Ocular Diseases (J.C., X.W., M.L., L.L., L.Z., J.X., B.L., X.Zho., D.W., M.D., X.Zha., X.L., Y.Z., H.L.), Guangzhou, Guangdong.
Purpose:
To develop a multimodal artificial intelligence (AI) system, EE-Explorer, to triage eye emergencies and assist in primary diagnosis using metadata and ocular images.
Design:
A diagnostic, cross-sectional, validity and reliability study.
Methods:
EE-Explorer consists of 2 models. The triage model was developed from metadata (events, symptoms, and medical history) and ocular surface images via smartphones from 2038 patients presenting to Zhongshan Ophthalmic Center (ZOC) to output 3 classifications: urgent, semiurgent, and nonurgent. The primary diagnostic model was developed from the paired metadata and slitlamp images of 2405 patients from ZOC. Both models were externally tested on 103 participants from 4 other hospitals. A pilot test was conducted in Guangzhou to evaluate the hierarchical referral service pattern assisted by EE-Explorer for unspecialized health care facilities.
Results:
A high overall accuracy, as indicated by an area under the receiver operating characteristic curve (AUC) of 0.982 (95% CI, 0.966-0.998), was obtained using the triage model, which outperformed the triage nurses (P < .001). In the primary diagnostic model, the diagnostic classification accuracy (CA) and Hamming loss (HL) in the internal testing were 0.808 (95% CI 0.776-0.840) and 0.016 (95% CI 0.006-0.026), respectively. In the external testing, model performance was robust for both triage (average AUC, 0.988, 95% CI 0.967-1.000) and primary diagnosis (CA, 0.718, 95% CI 0.644-0.792; and HL, 0.023, 95% CI 0.000-0.048). In the pilot test in the hierarchical referral settings, EE-explorer demonstrated consistently robust performance and broad participant acceptance.
Conclusion:
The EE-Explorer system showed robust performance in both triage and primary diagnosis for ophthalmic emergency patients. EE-Explorer can provide patients with acute ophthalmic symptoms access to remote self-triage and assist in primary diagnosis in unspecialized health care facilities to achieve rapid and effective treatment strategies.