Related Experiment Video
Updated: Jul 31, 2025

Biochemical Measurement of Neonatal Hypoxia
Published on: August 24, 2011
Measuring Oxygenation in Newborn Infants with Targeted Oxygen Ranges (MONITOR): a randomised crossover pilot study
Fraser G Christie1,2, Rod Kelly3,2, James P Boardman3,4
1Neonatology, Simpson Centre for Reproductive Health, NHS Lothian University Hospitals Division, Edinburgh, UK fraser.christie@nhs.scot.
Objective:
The Neonatal Oxygenation Prospective Meta-analysis (NeOProM) Collaboration showed that high (91-95%) versus low (85-89%) SpO2 targets reduced mortality. Trials of higher targets are needed to determine whether any more survival advantage may be gained. This pilot study explored the achieved oxygenation patterns observed when targeting SpO2 92-97% to facilitate the design of future trials.
Design:
Single-centre prospective randomised crossover pilot study. Manual FiO2 adjustment. Study time 12 hours per infant. 6 hours targeting SpO2 90-95% and 6 hours targeting SpO2 92-97%.
Patients:
Twenty preterm infants born <29 weeks' gestation, greater than 48 hours old, receiving supplemental oxygen.
Outcomes:
Primary outcome was percentage time with SpO2 above 97% and below 90%. Pre-defined secondary outcomes included percentage time spent within, above or below transcutaneous PO2 (TcPO2) 6.7-10.7 kPa (50-80 mm Hg). Comparisons were made using paired-samples t-test (2-tailed).
Results:
With SpO2 target 92-97% versus 90-95%, the mean (IQR) percentage time above SpO2 97% was 11.3% (2.7-20.9) versus 7.8% (1.7-13.9), p=0.02. Percentage time with SpO2 <90% was 13.1% (6.7-19.1) versus 17.9% (11.1-22.4), p=0.003. Percentage time with SpO2 <80% was 1% (0.1-1.4) versus 1.6% (0.4-2.6), p=0.119. Percentage time with TcPO2 <6.7 kPa (50 mm Hg) was 49.6% (30.2-66.0) versus 55% (34.3-73.5), p=0.63. Percentage time above TcPO2 10.7 kPa (80 mm Hg) was 1.4% (0-1.4) versus 1.8% (0-0), p=0.746.
Conclusions:
Targeting SpO2 92-97% produced a right shift in SpO2 and TcPO2 distribution, with reduced time at SpO2 <90% and increased time at SpO2 >97%, without increasing time with TcPO2 >10.7 kPa (80 mm Hg). Clinical trials targeting this higher SpO2 range could be conducted without significant hyperoxic exposure.
Trial Registration Number:
NCT03360292.
More Related Videos
11:39Non-invasive Optical Measurement of Cerebral Metabolism and Hemodynamics in Infants
Published on: March 14, 2013
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
Related Concept Videos
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Respiratory Assessment: Purpose and Indications
Objectives and Importance:
The primary goal of respiratory assessment is to evaluate patients at early risk of clinical deterioration. Since respiratory distress often precedes other signs of declining health, breathing patterns and sounds become a...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...