Related Experiment Video
Updated: Jul 31, 2025

Four-Dimensional CT Analysis Using Sequential 3D-3D Registration
Published on: November 23, 2019
Multi-Body 3D-2D Registration for Robot-Assisted Joint Reduction: Preclinical Evaluation in the Ankle Syndesmosis
R C Vijayan1, K Venkataraman1, J Wei1
1Department of Biomedical Engineering, Johns Hopkins University, Baltimore MD.
Purpose:
Existing methods to improve the accuracy of tibiofibular joint reduction present workflow challenges, high radiation exposure, and a lack of accuracy and precision, leading to poor surgical outcomes. To address these limitations, we propose a method to perform robot-assisted joint reduction using intraoperative imaging to align the dislocated fibula to a target pose relative to the tibia.
Methods:
The approach (1) localizes the robot via 3D-2D registration of a custom plate adapter attached to its end effector, (2) localizes the tibia and fibula using multi-body 3D-2D registration, and (3) drives the robot to reduce the dislocated fibula according to the target plan. The custom robot adapter was designed to interface directly with the fibular plate while presenting radiographic features to aid registration. Registration accuracy was evaluated on a cadaveric ankle specimen, and the feasibility of robotic guidance was assessed by manipulating a dislocated fibula in a cadaver ankle.
Results:
Using standard AP and mortise radiographic views registration errors were measured to be less than 1 mm and 1° for the robot adapter and the ankle bones. Experiments in a cadaveric specimen revealed up to 4 mm deviations from the intended path, which was reduced to <2 mm using corrective actions guided by intraoperative imaging and 3D-2D registration.
Conclusions:
Preclinical studies suggest that significant robot flex and tibial motion occur during fibula manipulation, motivating the use of the proposed method to dynamically correct the robot trajectory. Accurate robot registration was achieved via the use of fiducials embedded within the custom design. Future work will evaluate the approach on a custom radiolucent robot design currently under construction and verify the solution on additional cadaveric specimens.
Related Concept Videos
Ankle Joint
Joints
Structural joint classifications are based on the material that makes up the joint as well as whether or not the joint contains a space between the bones. Joints are structurally classified as fibrous, cartilaginous, or synovial.
Fibrous Joints Are Immovable
The bones of a...
Development of the Limb Synovial Joints
The mesenchymal stem cells differentiate into chondrocytes that form the hyaline cartilage, and later the cartilaginous model of the bone. This model further transforms into a bone. This process is known as endochondral ossification.
During development, the limbs...
Structural Classification of Joints
A fibrous joint is where the adjacent bones are united by fibrous connective...

