Related Experiment Video
Updated: Jul 31, 2025

Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
NCIRF: an organ dose calculator for patients undergoing radiography and fluoroscopy
Choonsik Lee1, Yeon Soo Yeom2, Jungwook Shin1
1Division of Cancer Epidemiology and Genetics, National Cancer Institute, National Institutes of Health, Rockville, MD, United States of America.
Abstract:
Background. It is critical to monitor the radiation dose delivered to patients undergoing radiography and fluoroscopy to prevent both acute and potential long-term adverse health effects. Accurate estimation of organ doses is essential to ensuring that radiation dose is maintained As Low As Reasonably Achievable. We developed a graphical user interface-based organ dose calculation tool for pediatric and adult patients undergoing radiography and fluoroscopy examinations.Methods. Our dose calculator follows the four sequential steps. First, the calculator obtains input parameters related to patient age and gender, and x-ray source data. Second, the program creates an input file describing the anatomy and material composition of a phantom, x-ray source, and organ dose scorers for Monte Carlo radiation transport using the user input parameters. Third, a built-in Geant4 module was developed to import the input file and to calculate organ absorbed doses and skeletal fluences through Monte Carlo radiation transport. Lastly, active marrow and endosteum doses are derived from the skeletal fluences and effective dose is calculated from the organ and tissue doses. Following benchmarking with MCNP6, we conducted some benchmarking calculations calculated organ doses for an illustrative cardeiac interventional fluoroscopy and compared the results with those from an existing dose calculator, PCXMC.Results. The graphical user interface-based program was entitled National Cancer Institute dosimetry system for Radiography and Fluoroscopy (NCIRF). Organ doses calculated from NCIRF showed an excellent agreement with those from MCNP6 in the simulation of an illustrative fluoroscopy exam. In the cardiac interventional fluoroscopy exam of the adult male and female phantoms, the lungs received relatively greater doses than any other organs. PCXMC based on stylistic phantoms overall overestimated major organ doses calculated from NCIRF by up to 3.7-fold (active bone marrow).Conclusion. We developed an organ dose calculation tool for pediatric and adult patients undergoing radiography and fluoroscopy examinations. NCIRF could substantially increase the accuracy and efficiency of organ dose estimation in radiography and fluoroscopy exams.
Related Concept Videos
Radiological Investigation I: X-ray and CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Biological Effects of Radiation
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies for Cardiovascular System V: CT